summaryrefslogtreecommitdiff
path: root/drivers/iio/adc
diff options
context:
space:
mode:
authorDumitru Ceclan <dumitru.ceclan@analog.com>2024-06-07 17:53:09 +0300
committerJonathan Cameron <Jonathan.Cameron@huawei.com>2024-06-25 21:04:32 +0100
commit98a563de231fcc91d65c6028c7f646fe28faf83a (patch)
treea0e824ea0e9cc579c4e2c216c826c17eba0f6b94 /drivers/iio/adc
parent561b5d5b7fbc1475e62ae68309f667ad2e18a669 (diff)
iio: adc: ad_sigma_delta: add disable_one callback
Sigma delta ADCs with a sequencer need to disable the previously enabled channel when reading using ad_sigma_delta_single_conversion(). This was done manually in drivers for devices with sequencers. This patch implements handling of single channel disabling after a single conversion. Reviewed-by: Nuno Sa <nuno.sa@analog.com> Signed-off-by: Dumitru Ceclan <dumitru.ceclan@analog.com> Reviewed-by: David Lechner <dlechner@baylibre.com> Link: https://patch.msgid.link/20240607-ad4111-v7-3-97e3855900a0@analog.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Diffstat (limited to 'drivers/iio/adc')
-rw-r--r--drivers/iio/adc/ad7124.c14
-rw-r--r--drivers/iio/adc/ad7173.c11
-rw-r--r--drivers/iio/adc/ad_sigma_delta.c1
3 files changed, 15 insertions, 11 deletions
diff --git a/drivers/iio/adc/ad7124.c b/drivers/iio/adc/ad7124.c
index e7b1d517d3de..3beed78496c5 100644
--- a/drivers/iio/adc/ad7124.c
+++ b/drivers/iio/adc/ad7124.c
@@ -555,10 +555,18 @@ static int ad7124_disable_all(struct ad_sigma_delta *sd)
return 0;
}
+static int ad7124_disable_one(struct ad_sigma_delta *sd, unsigned int chan)
+{
+ struct ad7124_state *st = container_of(sd, struct ad7124_state, sd);
+
+ return ad7124_spi_write_mask(st, AD7124_CHANNEL(chan), AD7124_CHANNEL_EN_MSK, 0, 2);
+}
+
static const struct ad_sigma_delta_info ad7124_sigma_delta_info = {
.set_channel = ad7124_set_channel,
.append_status = ad7124_append_status,
.disable_all = ad7124_disable_all,
+ .disable_one = ad7124_disable_one,
.set_mode = ad7124_set_mode,
.has_registers = true,
.addr_shift = 0,
@@ -582,12 +590,6 @@ static int ad7124_read_raw(struct iio_dev *indio_dev,
if (ret < 0)
return ret;
- /* After the conversion is performed, disable the channel */
- ret = ad_sd_write_reg(&st->sd, AD7124_CHANNEL(chan->address), 2,
- st->channels[chan->address].ain | AD7124_CHANNEL_EN(0));
- if (ret < 0)
- return ret;
-
return IIO_VAL_INT;
case IIO_CHAN_INFO_SCALE:
mutex_lock(&st->cfgs_lock);
diff --git a/drivers/iio/adc/ad7173.c b/drivers/iio/adc/ad7173.c
index b26d4575e256..428676c73722 100644
--- a/drivers/iio/adc/ad7173.c
+++ b/drivers/iio/adc/ad7173.c
@@ -569,10 +569,16 @@ static int ad7173_disable_all(struct ad_sigma_delta *sd)
return 0;
}
+static int ad7173_disable_one(struct ad_sigma_delta *sd, unsigned int chan)
+{
+ return ad_sd_write_reg(sd, AD7173_REG_CH(chan), 2, 0);
+}
+
static struct ad_sigma_delta_info ad7173_sigma_delta_info = {
.set_channel = ad7173_set_channel,
.append_status = ad7173_append_status,
.disable_all = ad7173_disable_all,
+ .disable_one = ad7173_disable_one,
.set_mode = ad7173_set_mode,
.has_registers = true,
.addr_shift = 0,
@@ -668,11 +674,6 @@ static int ad7173_read_raw(struct iio_dev *indio_dev,
if (ret < 0)
return ret;
- /* disable channel after single conversion */
- ret = ad_sd_write_reg(&st->sd, AD7173_REG_CH(chan->address), 2, 0);
- if (ret < 0)
- return ret;
-
return IIO_VAL_INT;
case IIO_CHAN_INFO_SCALE:
if (chan->type == IIO_TEMP) {
diff --git a/drivers/iio/adc/ad_sigma_delta.c b/drivers/iio/adc/ad_sigma_delta.c
index a2b87f6b7a07..8c062b0d26e3 100644
--- a/drivers/iio/adc/ad_sigma_delta.c
+++ b/drivers/iio/adc/ad_sigma_delta.c
@@ -321,6 +321,7 @@ out:
sigma_delta->keep_cs_asserted = false;
ad_sigma_delta_set_mode(sigma_delta, AD_SD_MODE_IDLE);
+ ad_sigma_delta_disable_one(sigma_delta, chan->address);
sigma_delta->bus_locked = false;
spi_bus_unlock(sigma_delta->spi->controller);
iio_device_release_direct_mode(indio_dev);