summaryrefslogtreecommitdiff
path: root/Documentation/hwmon/ds620.rst
diff options
context:
space:
mode:
authorMauro Carvalho Chehab <mchehab+samsung@kernel.org>2019-04-17 06:46:29 -0300
committerGuenter Roeck <linux@roeck-us.net>2019-04-17 10:37:23 -0700
commit7ebd8b66dd9e5a0b65e5ee5e2b8e7ca382ec97b7 (patch)
tree9db30159bd32bec125c7d49e80a79bb7c4da0c8e /Documentation/hwmon/ds620.rst
parentb04f2f7d387b3160883c2a1f5e2285483a791e82 (diff)
docs: hwmon: Add an index file and rename docs to *.rst
Now that all files were converted to ReST format, rename them and add an index. Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation/hwmon/ds620.rst')
-rw-r--r--Documentation/hwmon/ds620.rst38
1 files changed, 38 insertions, 0 deletions
diff --git a/Documentation/hwmon/ds620.rst b/Documentation/hwmon/ds620.rst
new file mode 100644
index 000000000000..2d686b17b547
--- /dev/null
+++ b/Documentation/hwmon/ds620.rst
@@ -0,0 +1,38 @@
+Kernel driver ds620
+===================
+
+Supported chips:
+
+ * Dallas Semiconductor DS620
+
+ Prefix: 'ds620'
+
+ Datasheet: Publicly available at the Dallas Semiconductor website
+
+ http://www.dalsemi.com/
+
+Authors:
+ Roland Stigge <stigge@antcom.de>
+ based on ds1621.c by
+ Christian W. Zuckschwerdt <zany@triq.net>
+
+Description
+-----------
+
+The DS620 is a (one instance) digital thermometer and thermostat. It has both
+high and low temperature limits which can be user defined (i.e. programmed
+into non-volatile on-chip registers). Temperature range is -55 degree Celsius
+to +125. Between 0 and 70 degree Celsius, accuracy is 0.5 Kelvin. The value
+returned via sysfs displays post decimal positions.
+
+The thermostat function works as follows: When configured via platform_data
+(struct ds620_platform_data) .pomode == 0 (default), the thermostat output pin
+PO is always low. If .pomode == 1, the thermostat is in PO_LOW mode. I.e., the
+output pin PO becomes active when the temperature falls below temp1_min and
+stays active until the temperature goes above temp1_max.
+
+Likewise, with .pomode == 2, the thermostat is in PO_HIGH mode. I.e., the PO
+output pin becomes active when the temperature goes above temp1_max and stays
+active until the temperature falls below temp1_min.
+
+The PO output pin of the DS620 operates active-low.