summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorLinus Torvalds <torvalds@linux-foundation.org>2022-11-12 09:27:15 -0800
committerLinus Torvalds <torvalds@linux-foundation.org>2022-11-12 09:27:15 -0800
commitfef7fd48922d11b22620e19f9c9101647bfe943d (patch)
treea52ac0393754164fbd56872359aab361e2f6e1aa
parentf95077acac6d3235735a41cc5f25a024777399dd (diff)
parentecb8c2580d37dbb641451049376d80c8afaa387f (diff)
Merge tag 'scsi-fixes' of git://git.kernel.org/pub/scm/linux/kernel/git/jejb/scsi
Pull SCSI fixes from James Bottomley: "Three small fixes, all in drivers. The sas one is in an unlikely error leg, the debug one is to make it more standards conformant and the ibmvfc one is to fix a user visible bug where a failover could lose all paths to the device" * tag 'scsi-fixes' of git://git.kernel.org/pub/scm/linux/kernel/git/jejb/scsi: scsi: scsi_debug: Make the READ CAPACITY response compliant with ZBC scsi: scsi_transport_sas: Fix error handling in sas_phy_add() scsi: ibmvfc: Avoid path failures during live migration
-rw-r--r--drivers/scsi/ibmvscsi/ibmvfc.c14
-rw-r--r--drivers/scsi/scsi_debug.c7
-rw-r--r--drivers/scsi/scsi_transport_sas.c13
3 files changed, 27 insertions, 7 deletions
diff --git a/drivers/scsi/ibmvscsi/ibmvfc.c b/drivers/scsi/ibmvscsi/ibmvfc.c
index 00684e11976b..1a0c0b7289d2 100644
--- a/drivers/scsi/ibmvscsi/ibmvfc.c
+++ b/drivers/scsi/ibmvscsi/ibmvfc.c
@@ -708,8 +708,13 @@ static void ibmvfc_init_host(struct ibmvfc_host *vhost)
memset(vhost->async_crq.msgs.async, 0, PAGE_SIZE);
vhost->async_crq.cur = 0;
- list_for_each_entry(tgt, &vhost->targets, queue)
- ibmvfc_del_tgt(tgt);
+ list_for_each_entry(tgt, &vhost->targets, queue) {
+ if (vhost->client_migrated)
+ tgt->need_login = 1;
+ else
+ ibmvfc_del_tgt(tgt);
+ }
+
scsi_block_requests(vhost->host);
ibmvfc_set_host_action(vhost, IBMVFC_HOST_ACTION_INIT);
vhost->job_step = ibmvfc_npiv_login;
@@ -3235,9 +3240,12 @@ static void ibmvfc_handle_crq(struct ibmvfc_crq *crq, struct ibmvfc_host *vhost,
/* We need to re-setup the interpartition connection */
dev_info(vhost->dev, "Partition migrated, Re-enabling adapter\n");
vhost->client_migrated = 1;
+
+ scsi_block_requests(vhost->host);
ibmvfc_purge_requests(vhost, DID_REQUEUE);
- ibmvfc_link_down(vhost, IBMVFC_LINK_DOWN);
+ ibmvfc_set_host_state(vhost, IBMVFC_LINK_DOWN);
ibmvfc_set_host_action(vhost, IBMVFC_HOST_ACTION_REENABLE);
+ wake_up(&vhost->work_wait_q);
} else if (crq->format == IBMVFC_PARTNER_FAILED || crq->format == IBMVFC_PARTNER_DEREGISTER) {
dev_err(vhost->dev, "Host partner adapter deregistered or failed (rc=%d)\n", crq->format);
ibmvfc_purge_requests(vhost, DID_ERROR);
diff --git a/drivers/scsi/scsi_debug.c b/drivers/scsi/scsi_debug.c
index 697fc57bc711..629853662b82 100644
--- a/drivers/scsi/scsi_debug.c
+++ b/drivers/scsi/scsi_debug.c
@@ -1899,6 +1899,13 @@ static int resp_readcap16(struct scsi_cmnd *scp,
arr[14] |= 0x40;
}
+ /*
+ * Since the scsi_debug READ CAPACITY implementation always reports the
+ * total disk capacity, set RC BASIS = 1 for host-managed ZBC devices.
+ */
+ if (devip->zmodel == BLK_ZONED_HM)
+ arr[12] |= 1 << 4;
+
arr[15] = sdebug_lowest_aligned & 0xff;
if (have_dif_prot) {
diff --git a/drivers/scsi/scsi_transport_sas.c b/drivers/scsi/scsi_transport_sas.c
index 2f88c61216ee..74b99f2b0b74 100644
--- a/drivers/scsi/scsi_transport_sas.c
+++ b/drivers/scsi/scsi_transport_sas.c
@@ -722,12 +722,17 @@ int sas_phy_add(struct sas_phy *phy)
int error;
error = device_add(&phy->dev);
- if (!error) {
- transport_add_device(&phy->dev);
- transport_configure_device(&phy->dev);
+ if (error)
+ return error;
+
+ error = transport_add_device(&phy->dev);
+ if (error) {
+ device_del(&phy->dev);
+ return error;
}
+ transport_configure_device(&phy->dev);
- return error;
+ return 0;
}
EXPORT_SYMBOL(sas_phy_add);