summaryrefslogtreecommitdiff
path: root/drivers/net/dsa/ocelot/ocelot_ext.c
blob: 22187d831c4b9f970b556e47d7cb59302797c58a (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
// SPDX-License-Identifier: (GPL-2.0 OR MIT)
/*
 * Copyright 2021-2022 Innovative Advantage Inc.
 */

#include <linux/mfd/ocelot.h>
#include <linux/platform_device.h>
#include <linux/regmap.h>
#include <soc/mscc/ocelot.h>
#include <soc/mscc/vsc7514_regs.h>
#include "felix.h"

#define VSC7514_NUM_PORTS		11

#define OCELOT_PORT_MODE_SERDES		(OCELOT_PORT_MODE_SGMII | \
					 OCELOT_PORT_MODE_QSGMII)

static const u32 vsc7512_port_modes[VSC7514_NUM_PORTS] = {
	OCELOT_PORT_MODE_INTERNAL,
	OCELOT_PORT_MODE_INTERNAL,
	OCELOT_PORT_MODE_INTERNAL,
	OCELOT_PORT_MODE_INTERNAL,
	OCELOT_PORT_MODE_SERDES,
	OCELOT_PORT_MODE_SERDES,
	OCELOT_PORT_MODE_SERDES,
	OCELOT_PORT_MODE_SERDES,
	OCELOT_PORT_MODE_SERDES,
	OCELOT_PORT_MODE_SGMII,
	OCELOT_PORT_MODE_SERDES,
};

static const struct ocelot_ops ocelot_ext_ops = {
	.reset		= ocelot_reset,
	.wm_enc		= ocelot_wm_enc,
	.wm_dec		= ocelot_wm_dec,
	.wm_stat	= ocelot_wm_stat,
	.port_to_netdev	= felix_port_to_netdev,
	.netdev_to_port	= felix_netdev_to_port,
};

static const char * const vsc7512_resource_names[TARGET_MAX] = {
	[SYS] = "sys",
	[REW] = "rew",
	[S0] = "s0",
	[S1] = "s1",
	[S2] = "s2",
	[QS] = "qs",
	[QSYS] = "qsys",
	[ANA] = "ana",
};

static const struct felix_info vsc7512_info = {
	.resource_names			= vsc7512_resource_names,
	.regfields			= vsc7514_regfields,
	.map				= vsc7514_regmap,
	.ops				= &ocelot_ext_ops,
	.vcap				= vsc7514_vcap_props,
	.num_mact_rows			= 1024,
	.num_ports			= VSC7514_NUM_PORTS,
	.num_tx_queues			= OCELOT_NUM_TC,
	.port_modes			= vsc7512_port_modes,
	.phylink_mac_config		= ocelot_phylink_mac_config,
	.configure_serdes		= ocelot_port_configure_serdes,
};

static int ocelot_ext_probe(struct platform_device *pdev)
{
	struct device *dev = &pdev->dev;
	struct dsa_switch *ds;
	struct ocelot *ocelot;
	struct felix *felix;
	int err;

	felix = kzalloc(sizeof(*felix), GFP_KERNEL);
	if (!felix)
		return -ENOMEM;

	dev_set_drvdata(dev, felix);

	ocelot = &felix->ocelot;
	ocelot->dev = dev;

	ocelot->num_flooding_pgids = 1;

	felix->info = &vsc7512_info;

	ds = kzalloc(sizeof(*ds), GFP_KERNEL);
	if (!ds) {
		err = -ENOMEM;
		dev_err_probe(dev, err, "Failed to allocate DSA switch\n");
		goto err_free_felix;
	}

	ds->dev = dev;
	ds->num_ports = felix->info->num_ports;
	ds->num_tx_queues = felix->info->num_tx_queues;

	ds->ops = &felix_switch_ops;
	ds->priv = ocelot;
	felix->ds = ds;
	felix->tag_proto = DSA_TAG_PROTO_OCELOT;

	err = dsa_register_switch(ds);
	if (err) {
		dev_err_probe(dev, err, "Failed to register DSA switch\n");
		goto err_free_ds;
	}

	return 0;

err_free_ds:
	kfree(ds);
err_free_felix:
	kfree(felix);
	return err;
}

static void ocelot_ext_remove(struct platform_device *pdev)
{
	struct felix *felix = dev_get_drvdata(&pdev->dev);

	if (!felix)
		return;

	dsa_unregister_switch(felix->ds);

	kfree(felix->ds);
	kfree(felix);
}

static void ocelot_ext_shutdown(struct platform_device *pdev)
{
	struct felix *felix = dev_get_drvdata(&pdev->dev);

	if (!felix)
		return;

	dsa_switch_shutdown(felix->ds);

	dev_set_drvdata(&pdev->dev, NULL);
}

static const struct of_device_id ocelot_ext_switch_of_match[] = {
	{ .compatible = "mscc,vsc7512-switch" },
	{ },
};
MODULE_DEVICE_TABLE(of, ocelot_ext_switch_of_match);

static struct platform_driver ocelot_ext_switch_driver = {
	.driver = {
		.name = "ocelot-ext-switch",
		.of_match_table = ocelot_ext_switch_of_match,
	},
	.probe = ocelot_ext_probe,
	.remove_new = ocelot_ext_remove,
	.shutdown = ocelot_ext_shutdown,
};
module_platform_driver(ocelot_ext_switch_driver);

MODULE_DESCRIPTION("External Ocelot Switch driver");
MODULE_LICENSE("GPL");
MODULE_IMPORT_NS(MFD_OCELOT);