1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
|
# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
%YAML 1.2
---
$id: http://devicetree.org/schemas/thermal/nvidia,tegra124-soctherm.yaml#
$schema: http://devicetree.org/meta-schemas/core.yaml#
title: NVIDIA Tegra124 SOCTHERM Thermal Management System
maintainers:
- Thierry Reding <thierry.reding@gmail.com>
- Jon Hunter <jonathanh@nvidia.com>
description: The SOCTHERM IP block contains thermal sensors, support for
polled or interrupt-based thermal monitoring, CPU and GPU throttling based
on temperature trip points, and handling external overcurrent notifications.
It is also used to manage emergency shutdown in an overheating situation.
properties:
compatible:
enum:
- nvidia,tegra124-soctherm
- nvidia,tegra132-soctherm
- nvidia,tegra210-soctherm
reg:
maxItems: 2
reg-names:
maxItems: 2
interrupts:
items:
- description: module interrupt
- description: EDP interrupt
interrupt-names:
items:
- const: thermal
- const: edp
clocks:
items:
- description: thermal sensor clock
- description: module clock
clock-names:
items:
- const: tsensor
- const: soctherm
resets:
items:
- description: module reset
reset-names:
items:
- const: soctherm
"#thermal-sensor-cells":
const: 1
throttle-cfgs:
$ref: thermal-cooling-devices.yaml
description: A sub-node which is a container of configuration for each
hardware throttle events. These events can be set as cooling devices.
Throttle event sub-nodes must be named as "light" or "heavy".
unevaluatedProperties: false
patternProperties:
"^(light|heavy|oc1)$":
type: object
additionalProperties: false
properties:
"#cooling-cells":
const: 2
nvidia,priority:
$ref: /schemas/types.yaml#/definitions/uint32
minimum: 1
maximum: 100
description: Each throttles has its own throttle settings, so the
SW need to set priorities for various throttle, the HW arbiter
can select the final throttle settings. Bigger value indicates
higher priority, In general, higher priority translates to lower
target frequency. SW needs to ensure that critical thermal
alarms are given higher priority, and ensure that there is no
race if priority of two vectors is set to the same value.
nvidia,cpu-throt-percent:
description: This property is for Tegra124 and Tegra210. It is the
throttling depth of pulse skippers, it's the percentage
throttling.
minimum: 0
maximum: 100
nvidia,cpu-throt-level:
$ref: /schemas/types.yaml#/definitions/uint32
description: This property is only for Tegra132, it is the level
of pulse skippers, which used to throttle clock frequencies. It
indicates cpu clock throttling depth, and the depth can be
programmed.
enum:
# none (TEGRA_SOCTHERM_THROT_LEVEL_NONE)
- 0
# low (TEGRA_SOCTHERM_THROT_LEVEL_LOW)
- 1
# medium (TEGRA_SOCTHERM_THROT_LEVEL_MED)
- 2
# high (TEGRA_SOCTHERM_THROT_LEVEL_HIGH)
- 3
nvidia,gpu-throt-level:
$ref: /schemas/types.yaml#/definitions/uint32
description: This property is for Tegra124 and Tegra210. It is the
level of pulse skippers, which used to throttle clock
frequencies. It indicates gpu clock throttling depth and can be
programmed to any of the following values which represent a
throttling percentage.
enum:
# none (0%, TEGRA_SOCTHERM_THROT_LEVEL_NONE)
- 0
# low (50%, TEGRA_SOCTHERM_THROT_LEVEL_LOW)
- 1
# medium (75%, TEGRA_SOCTHERM_THROT_LEVEL_MED)
- 2
# high (85%, TEGRA_SOCTHERM_THROT_LEVEL_HIGH)
- 3
# optional
# Tegra210 specific and valid only for OCx throttle events
nvidia,count-threshold:
$ref: /schemas/types.yaml#/definitions/uint32
description: Specifies the number of OC events that are required
for triggering an interrupt. Interrupts are not triggered if the
property is missing. A value of 0 will interrupt on every OC
alarm.
nvidia,polarity-active-low:
$ref: /schemas/types.yaml#/definitions/flag
description: Configures the polarity of the OC alaram signal. If
present, this means assert low, otherwise assert high.
nvidia,alarm-filter:
$ref: /schemas/types.yaml#/definitions/uint32
description: Number of clocks to filter event. When the filter
expires (which means the OC event has not occurred for a long
time), the counter is cleared and filter is rearmed.
default: 0
nvidia,throttle-period-us:
description: Specifies the number of microseconds for which
throttling is engaged after the OC event is deasserted.
default: 0
# optional
nvidia,thermtrips:
$ref: /schemas/types.yaml#/definitions/uint32-matrix
description: |
When present, this property specifies the temperature at which the
SOCTHERM hardware will assert the thermal trigger signal to the Power
Management IC, which can be configured to reset or shutdown the device.
It is an array of pairs where each pair represents a tsensor ID followed
by a temperature in milli Celcius. In the absence of this property the
critical trip point will be used for thermtrip temperature.
Note:
- the "critical" type trip points will be used to set the temperature at
which the SOCTHERM hardware will assert a thermal trigger if the
"nvidia,thermtrips" property is missing. When the thermtrips property
is present, the breach of a critical trip point is reported back to
the thermal framework to implement software shutdown.
- the "hot" type trip points will be set to SOCTHERM hardware as the
throttle temperature. Once the temperature of this thermal zone is
higher than it, it will trigger the HW throttle event.
items:
items:
- description: sensor ID
oneOf:
- description: CPU sensor
const: 0
- description: MEM sensor
const: 1
- description: GPU sensor
const: 2
- description: PLLX sensor
const: 3
- description: temperature threshold (in millidegree Celsius)
required:
- compatible
- reg
- reg-names
- interrupts
- interrupt-names
- clocks
- clock-names
- resets
- reset-names
allOf:
- $ref: thermal-sensor.yaml
- if:
properties:
compatible:
contains:
enum:
- nvidia,tegra124-soctherm
- nvidia,tegra210-soctherm
then:
properties:
reg:
items:
- description: SOCTHERM register set
- description: clock and reset controller registers
reg-names:
items:
- const: soctherm-reg
- const: car-reg
else:
properties:
reg:
items:
- description: SOCTHERM register set
- description: CCROC registers
reg-names:
items:
- const: soctherm-reg
- const: ccroc-reg
additionalProperties: false
examples:
- |
#include <dt-bindings/clock/tegra124-car.h>
#include <dt-bindings/interrupt-controller/arm-gic.h>
#include <dt-bindings/thermal/tegra124-soctherm.h>
soctherm@700e2000 {
compatible = "nvidia,tegra124-soctherm";
reg = <0x700e2000 0x600>, /* SOC_THERM reg_base */
<0x60006000 0x400>; /* CAR reg_base */
reg-names = "soctherm-reg", "car-reg";
interrupts = <GIC_SPI 48 IRQ_TYPE_LEVEL_HIGH>,
<GIC_SPI 51 IRQ_TYPE_LEVEL_HIGH>;
interrupt-names = "thermal", "edp";
clocks = <&tegra_car TEGRA124_CLK_TSENSOR>,
<&tegra_car TEGRA124_CLK_SOC_THERM>;
clock-names = "tsensor", "soctherm";
resets = <&tegra_car 78>;
reset-names = "soctherm";
#thermal-sensor-cells = <1>;
nvidia,thermtrips = <TEGRA124_SOCTHERM_SENSOR_CPU 102500>,
<TEGRA124_SOCTHERM_SENSOR_GPU 103000>;
throttle-cfgs {
/*
* When the "heavy" cooling device triggered,
* the HW will skip cpu clock's pulse in 85% depth,
* skip gpu clock's pulse in 85% level
*/
heavy {
nvidia,priority = <100>;
nvidia,cpu-throt-percent = <85>;
nvidia,gpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_HIGH>;
#cooling-cells = <2>;
};
/*
* When the "light" cooling device triggered,
* the HW will skip cpu clock's pulse in 50% depth,
* skip gpu clock's pulse in 50% level
*/
light {
nvidia,priority = <80>;
nvidia,cpu-throt-percent = <50>;
nvidia,gpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_LOW>;
#cooling-cells = <2>;
};
/*
* If these two devices are triggered in same time, the HW throttle
* arbiter will select the highest priority as the final throttle
* settings to skip cpu pulse.
*/
oc1 {
nvidia,priority = <50>;
nvidia,polarity-active-low;
nvidia,count-threshold = <100>;
nvidia,alarm-filter = <5100000>;
nvidia,throttle-period-us = <0>;
nvidia,cpu-throt-percent = <75>;
nvidia,gpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_MED>;
};
};
};
# referring to Tegra132's "reg", "reg-names" and "throttle-cfgs"
- |
thermal-sensor@700e2000 {
compatible = "nvidia,tegra132-soctherm";
reg = <0x700e2000 0x600>, /* SOC_THERM reg_base */
<0x70040000 0x200>; /* CCROC reg_base */
reg-names = "soctherm-reg", "ccroc-reg";
interrupts = <GIC_SPI 48 IRQ_TYPE_LEVEL_HIGH>,
<GIC_SPI 51 IRQ_TYPE_LEVEL_HIGH>;
interrupt-names = "thermal", "edp";
clocks = <&tegra_car TEGRA124_CLK_TSENSOR>,
<&tegra_car TEGRA124_CLK_SOC_THERM>;
clock-names = "tsensor", "soctherm";
resets = <&tegra_car 78>;
reset-names = "soctherm";
#thermal-sensor-cells = <1>;
throttle-cfgs {
/*
* When the "heavy" cooling device triggered,
* the HW will skip cpu clock's pulse in HIGH level
*/
heavy {
nvidia,priority = <100>;
nvidia,cpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_HIGH>;
#cooling-cells = <2>;
};
/*
* When the "light" cooling device triggered,
* the HW will skip cpu clock's pulse in MED level
*/
light {
nvidia,priority = <80>;
nvidia,cpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_MED>;
#cooling-cells = <2>;
};
/*
* If these two devices are triggered in same time, the HW throttle
* arbiter will select the highest priority as the final throttle
* settings to skip cpu pulse.
*/
};
};
# referring to thermal sensors
- |
thermal-zones {
cpu-thermal {
polling-delay-passive = <1000>;
polling-delay = <1000>;
thermal-sensors = <&soctherm TEGRA124_SOCTHERM_SENSOR_CPU>;
trips {
cpu_shutdown_trip: shutdown-trip {
temperature = <102500>;
hysteresis = <1000>;
type = "critical";
};
cpu_throttle_trip: throttle-trip {
temperature = <100000>;
hysteresis = <1000>;
type = "hot";
};
};
cooling-maps {
map0 {
trip = <&cpu_throttle_trip>;
cooling-device = <&throttle_heavy 1 1>;
};
};
};
};
|