diff options
author | David Lechner <david@lechnology.com> | 2018-05-25 13:11:42 -0500 |
---|---|---|
committer | Michael Turquette <mturquette@baylibre.com> | 2018-05-30 12:47:49 -0700 |
commit | b4d73d224d9bc6881266fd95ab11ef738ef7333f (patch) | |
tree | a40b5a8363cb3fd560638599f5aae72785d90efd /drivers/clk/davinci | |
parent | 60cc43fc888428bb2f18f08997432d426a243338 (diff) |
clk: davinci: pll-dm355: drop pll2_sysclk2
This removes pll2_sysclk2 from the TI DM355 clock driver. This SoC
doesn't have such a clock. Also, SYSCLK_ALWAYS_ENABLED is transferred
to pll2_sysclk1 since it drives the DDR and doesn't have another
mechanism to keep it on.
Reported-by: Sekhar Nori <nsekhar@ti.com>
Signed-off-by: David Lechner <david@lechnology.com>
Acked-by: Sekhar Nori <nsekhar@ti.com>
Signed-off-by: Michael Turquette <mturquette@baylibre.com>
Link: lkml.kernel.org/r/20180525181150.17873-2-david@lechnology.com
Diffstat (limited to 'drivers/clk/davinci')
-rw-r--r-- | drivers/clk/davinci/pll-dm355.c | 5 |
1 files changed, 1 insertions, 4 deletions
diff --git a/drivers/clk/davinci/pll-dm355.c b/drivers/clk/davinci/pll-dm355.c index 5345f8286c50..718d9bbbf30d 100644 --- a/drivers/clk/davinci/pll-dm355.c +++ b/drivers/clk/davinci/pll-dm355.c @@ -62,8 +62,7 @@ static const struct davinci_pll_clk_info dm355_pll2_info = { PLL_POSTDIV_ALWAYS_ENABLED | PLL_POSTDIV_FIXED_DIV, }; -SYSCLK(1, pll2_sysclk1, pll2, 5, SYSCLK_FIXED_DIV); -SYSCLK(2, pll2_sysclk2, pll2, 5, SYSCLK_FIXED_DIV | SYSCLK_ALWAYS_ENABLED); +SYSCLK(1, pll2_sysclk1, pll2, 5, SYSCLK_FIXED_DIV | SYSCLK_ALWAYS_ENABLED); int dm355_pll2_init(struct device *dev, void __iomem *base) { @@ -71,8 +70,6 @@ int dm355_pll2_init(struct device *dev, void __iomem *base) davinci_pll_sysclk_register(dev, &pll2_sysclk1, base); - davinci_pll_sysclk_register(dev, &pll2_sysclk2, base); - davinci_pll_sysclkbp_clk_register(dev, "pll2_sysclkbp", base); return 0; |