summaryrefslogtreecommitdiff
path: root/include/uapi/linux/thermal.h
AgeCommit message (Collapse)Author
2022-02-03thermal: netlink: Add a new event to notify CPU capabilities changeSrinivas Pandruvada
Add a new netlink event to notify change in CPU capabilities in terms of performance and efficiency. Firmware may change CPU capabilities as a result of thermal events in the system or to account for changes in the TDP (thermal design power) level. This notification type will allow user space to avoid running workloads on certain CPUs or proactively adjust power limits to avoid future events. The netlink message consists of a nested attribute (THERMAL_GENL_ATTR_CPU_CAPABILITY) with three attributes: * THERMAL_GENL_ATTR_CPU_CAPABILITY_ID (type u32): -- logical CPU number * THERMAL_GENL_ATTR_CPU_CAPABILITY_PERFORMANCE (type u32): -- Scaled performance from 0-1023 * THERMAL_GENL_ATTR_CPU_CAPABILITY_EFFICIENCY (type u32): -- Scaled efficiency from 0-1023 Reviewed-by: Len Brown <len.brown@intel.com> Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com> Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2021-03-11thermal: Fix spelling mistake "disabed" -> "disabled"Colin Ian King
There is a spelling mistake in a comment, fix it. Signed-off-by: Colin Ian King <colin.king@canonical.com> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://lore.kernel.org/r/20210311093054.5338-1-colin.king@canonical.com
2020-07-07thermal: core: genetlink support for events/cmd/samplingDaniel Lezcano
Initially the thermal framework had a very simple notification mechanism to send generic netlink messages to the userspace. The notification function was never called from anywhere and the corresponding dead code was removed. It was probably a first attempt to introduce the netlink notification. At LPC2018, the presentation "Linux thermal: User kernel interface", proposed to create the notifications to the userspace via a kfifo. The advantage of the kfifo is the performance. It is usually used from a 1:1 communication channel where a driver captures data and sends it as fast as possible to a userspace process. The drawback is that only one process uses the notification channel exclusively, thus no other process is allowed to use the channel to get temperature or notifications. This patch defines a generic netlink API to discover the current thermal setup and adds event notifications as well as temperature sampling. As any genetlink protocol, it can evolve and the versioning allows to keep the backward compatibility. In order to prevent the user from getting flooded with data on a single channel, there are two multicast channels, one for the temperature sampling when the thermal zone is updated and another one for the events, so the user can get the events only without the thermal zone temperature sampling. Also, a list of commands to discover the thermal setup is added and can be extended when needed. Reviewed-by: Amit Kucheria <amit.kucheria@linaro.org> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Acked-by: Zhang Rui <rui.zhang@intel.com> Link: https://lore.kernel.org/r/20200706105538.2159-3-daniel.lezcano@linaro.org
2017-11-02License cleanup: add SPDX license identifier to uapi header files with no ↵Greg Kroah-Hartman
license Many user space API headers are missing licensing information, which makes it hard for compliance tools to determine the correct license. By default are files without license information under the default license of the kernel, which is GPLV2. Marking them GPLV2 would exclude them from being included in non GPLV2 code, which is obviously not intended. The user space API headers fall under the syscall exception which is in the kernels COPYING file: NOTE! This copyright does *not* cover user programs that use kernel services by normal system calls - this is merely considered normal use of the kernel, and does *not* fall under the heading of "derived work". otherwise syscall usage would not be possible. Update the files which contain no license information with an SPDX license identifier. The chosen identifier is 'GPL-2.0 WITH Linux-syscall-note' which is the officially assigned identifier for the Linux syscall exception. SPDX license identifiers are a legally binding shorthand, which can be used instead of the full boiler plate text. This patch is based on work done by Thomas Gleixner and Kate Stewart and Philippe Ombredanne. See the previous patch in this series for the methodology of how this patch was researched. Reviewed-by: Kate Stewart <kstewart@linuxfoundation.org> Reviewed-by: Philippe Ombredanne <pombredanne@nexb.com> Reviewed-by: Thomas Gleixner <tglx@linutronix.de> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2014-12-09thermal: provide an UAPI header fileFlorian Fainelli
include/linux/thermal.h contains definitions for the Thermal generic netlink family, but none of the valuable information relevant to user-space such as the Genl family name, multicast group, version or command set and data types is exported to user-space. Export all the relevant generic netlink information to user-space to make this genl family usable by user-space, and while at it, export THERMAL_NAME_LENGTH since it limits name length for thermal_hwmon devices. Kbuild and MAINTAINERS are also updated accordingly to reflect this new file: include/uapi/linux/thermal.h. Signed-off-by: Florian Fainelli <f.fainelli@gmail.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com>