Age | Commit message (Collapse) | Author |
|
This allows to drop the platform_driver's remove function. This is the
only user of driver data so this can go away, too.
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
|
|
Since commit 5e5da1e9fbee ("pwm: ab8500: Explicitly allocate pwm chip
base dynamically") all drivers use dynamic ID allocation explicitly. New
drivers are supposed to do the same, so remove support for driver
specified base IDs and drop all assignments in the low-level drivers.
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
|
|
If duty cycle is first set to a value that is sufficiently high to
enable the output (e.g. 10000 ns) but then lowered to a value that
is quantized to zero (e.g. 1000 ns), the output is disabled as the
device cannot drive a constant zero (as expected).
However if the device is later re-initialized due to watchdog bite,
the output is re-enabled at the next-to-last duty cycle (10000 ns).
This is because the iqs620_pwm->out_en flag unconditionally tracks
state->enabled instead of what was actually written to the device.
To solve this problem, use one state variable that encodes all 257
states of the output (duty_scale) with 0 representing tri-state, 1
representing the minimum available duty cycle and 256 representing
100% duty cycle.
Signed-off-by: Jeff LaBundy <jeff@labundy.com>
Reviewed-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
|
|
If state->duty_cycle is 0x100000000000000, the previous calculation of
duty_scale overflows and yields a duty cycle ratio of 0% instead of
100%. Fix this by clamping the requested duty cycle to the maximal
possible duty cycle first. This way it is possible to use a native
integer division instead of a (depending on the architecture) more
expensive 64bit division.
With this change in place duty_scale cannot be bigger than 256 which
allows to simplify the calculation of duty_val.
Fixes: 6f0841a8197b ("pwm: Add support for Azoteq IQS620A PWM generator")
Tested-by: Jeff LaBundy <jeff@labundy.com>
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
|
|
Instead of using a mix of -EOPNOTSUPP and -ENOTSUPP, use the more
standard -EINVAL to signal that the specified polarity value was
invalid.
Acked-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Acked-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
|
|
Other drivers use lowercase hexadecimal literals, so convert the IQS620a
driver to do the same for consistency.
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
|
|
The PWM framework is going to change the PWM period and duty cycles to
be 64-bit unsigned integers. To avoid build errors on platforms that do
not natively support 64-bit division, use explicity 64-bit division.
Acked-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Acked-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
|
|
This patch adds support for the Azoteq IQS620A, capable of generating
a 1-kHz PWM output with duty cycle between ~0.4% and 100% (inclusive).
Signed-off-by: Jeff LaBundy <jeff@labundy.com>
Reviewed-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
|