diff options
Diffstat (limited to 'tools/perf/pmu-events/arch/s390/cf_z16/extended.json')
-rw-r--r-- | tools/perf/pmu-events/arch/s390/cf_z16/extended.json | 62 |
1 files changed, 31 insertions, 31 deletions
diff --git a/tools/perf/pmu-events/arch/s390/cf_z16/extended.json b/tools/perf/pmu-events/arch/s390/cf_z16/extended.json index c2b10ec1c6e0..02cce3a629cb 100644 --- a/tools/perf/pmu-events/arch/s390/cf_z16/extended.json +++ b/tools/perf/pmu-events/arch/s390/cf_z16/extended.json @@ -94,77 +94,77 @@ "Unit": "CPU-M-CF", "EventCode": "145", "EventName": "DCW_REQ", - "BriefDescription": "Directory Write Level 1 Data Cache from Cache", + "BriefDescription": "Directory Write Level 1 Data Cache from L2-Cache", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the requestors Level-2 cache." }, { "Unit": "CPU-M-CF", "EventCode": "146", "EventName": "DCW_REQ_IV", - "BriefDescription": "Directory Write Level 1 Data Cache from Cache with Intervention", + "BriefDescription": "Directory Write Level 1 Data Cache from L2-Cache with Intervention", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the requestors Level-2 cache with intervention." }, { "Unit": "CPU-M-CF", "EventCode": "147", "EventName": "DCW_REQ_CHIP_HIT", - "BriefDescription": "Directory Write Level 1 Data Cache from Cache with Chip HP Hit", + "BriefDescription": "Directory Write Level 1 Data Cache from L2-Cache with Chip HP Hit", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the requestors Level-2 cache after using chip level horizontal persistence, Chip-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "148", "EventName": "DCW_REQ_DRAWER_HIT", - "BriefDescription": "Directory Write Level 1 Data Cache from Cache with Drawer HP Hit", + "BriefDescription": "Directory Write Level 1 Data Cache from L2-Cache with Drawer HP Hit", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the requestors Level-2 cache after using drawer level horizontal persistence, Drawer-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "149", "EventName": "DCW_ON_CHIP", - "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip Cache", + "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip L2-Cache", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-2 cache." }, { "Unit": "CPU-M-CF", "EventCode": "150", "EventName": "DCW_ON_CHIP_IV", - "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip Cache with Intervention", + "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip L2-Cache with Intervention", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-2 cache with intervention." }, { "Unit": "CPU-M-CF", "EventCode": "151", "EventName": "DCW_ON_CHIP_CHIP_HIT", - "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip Cache with Chip HP Hit", + "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip L2-Cache with Chip HP Hit", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-2 cache after using chip level horizontal persistence, Chip-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "152", "EventName": "DCW_ON_CHIP_DRAWER_HIT", - "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip Cache with Drawer HP Hit", + "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip L2-Cache with Drawer HP Hit", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-2 cache using drawer level horizontal persistence, Drawer-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "153", "EventName": "DCW_ON_MODULE", - "BriefDescription": "Directory Write Level 1 Data Cache from On-Module Cache", + "BriefDescription": "Directory Write Level 1 Data Cache from On-Module L2-Cache", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Module Level-2 cache." }, { "Unit": "CPU-M-CF", "EventCode": "154", "EventName": "DCW_ON_DRAWER", - "BriefDescription": "Directory Write Level 1 Data Cache from On-Drawer Cache", + "BriefDescription": "Directory Write Level 1 Data Cache from On-Drawer L2-Cache", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Drawer Level-2 cache." }, { "Unit": "CPU-M-CF", "EventCode": "155", "EventName": "DCW_OFF_DRAWER", - "BriefDescription": "Directory Write Level 1 Data Cache from Off-Drawer Cache", + "BriefDescription": "Directory Write Level 1 Data Cache from Off-Drawer L2-Cache", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Level-2 cache." }, { @@ -199,140 +199,140 @@ "Unit": "CPU-M-CF", "EventCode": "160", "EventName": "IDCW_ON_MODULE_IV", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory Cache with Intervention", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory L2-Cache with Intervention", "PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an On-Module Level-2 cache with intervention." }, { "Unit": "CPU-M-CF", "EventCode": "161", "EventName": "IDCW_ON_MODULE_CHIP_HIT", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory Cache with Chip Hit", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory L2-Cache with Chip Hit", "PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an On-Module Level-2 cache using chip horizontal persistence, Chip-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "162", "EventName": "IDCW_ON_MODULE_DRAWER_HIT", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory Cache with Drawer Hit", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory L2-Cache with Drawer Hit", "PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an On-Module Level-2 cache using drawer level horizontal persistence, Drawer-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "163", "EventName": "IDCW_ON_DRAWER_IV", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer Cache with Intervention", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer L2-Cache with Intervention", "PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an On-Drawer Level-2 cache with intervention." }, { "Unit": "CPU-M-CF", "EventCode": "164", "EventName": "IDCW_ON_DRAWER_CHIP_HIT", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer Cache with Chip Hit", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer L2-Cache with Chip Hit", "PublicDescription": "A directory write to the Level-1 Data or Level-1 instruction cache directory where the returned cache line was sourced from an On-Drawer Level-2 cache using chip level horizontal persistence, Chip-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "165", "EventName": "IDCW_ON_DRAWER_DRAWER_HIT", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer Cache with Drawer Hit", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer L2-Cache with Drawer Hit", "PublicDescription": "A directory write to the Level-1 Data or Level-1 instruction cache directory where the returned cache line was sourced from an On-Drawer Level-2 cache using drawer level horizontal persistence, Drawer-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "166", "EventName": "IDCW_OFF_DRAWER_IV", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer Cache with Intervention", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer L2-Cache with Intervention", "PublicDescription": "A directory write to the Level-1 Data or Level-1 instruction cache directory where the returned cache line was sourced from an Off-Drawer Level-2 cache with intervention." }, { "Unit": "CPU-M-CF", "EventCode": "167", "EventName": "IDCW_OFF_DRAWER_CHIP_HIT", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer Cache with Chip Hit", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer L2-Cache with Chip Hit", "PublicDescription": "A directory write to the Level-1 Data or Level-1 instruction cache directory where the returned cache line was sourced from an Off-Drawer Level-2 cache using chip level horizontal persistence, Chip-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "168", "EventName": "IDCW_OFF_DRAWER_DRAWER_HIT", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer Cache with Drawer Hit", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer L2-Cache with Drawer Hit", "PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Level-2 cache using drawer level horizontal persistence, Drawer-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "169", "EventName": "ICW_REQ", - "BriefDescription": "Directory Write Level 1 Instruction Cache from Cache", + "BriefDescription": "Directory Write Level 1 Instruction Cache from L2-Cache", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced the requestors Level-2 cache." }, { "Unit": "CPU-M-CF", "EventCode": "170", "EventName": "ICW_REQ_IV", - "BriefDescription": "Directory Write Level 1 Instruction Cache from Cache with Intervention", + "BriefDescription": "Directory Write Level 1 Instruction Cache from L2-Cache with Intervention", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from the requestors Level-2 cache with intervention." }, { "Unit": "CPU-M-CF", "EventCode": "171", "EventName": "ICW_REQ_CHIP_HIT", - "BriefDescription": "Directory Write Level 1 Instruction Cache from Cache with Chip HP Hit", + "BriefDescription": "Directory Write Level 1 Instruction Cache from L2-Cache with Chip HP Hit", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from the requestors Level-2 cache using chip level horizontal persistence, Chip-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "172", "EventName": "ICW_REQ_DRAWER_HIT", - "BriefDescription": "Directory Write Level 1 Instruction Cache from Cache with Drawer HP Hit", + "BriefDescription": "Directory Write Level 1 Instruction Cache from L2-Cache with Drawer HP Hit", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from the requestors Level-2 cache using drawer level horizontal persistence, Drawer-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "173", "EventName": "ICW_ON_CHIP", - "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip Cache", + "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip L2-Cache", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Chip Level-2 cache." }, { "Unit": "CPU-M-CF", "EventCode": "174", "EventName": "ICW_ON_CHIP_IV", - "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip Cache with Intervention", + "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip L2-Cache with Intervention", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced an On-Chip Level-2 cache with intervention." }, { "Unit": "CPU-M-CF", "EventCode": "175", "EventName": "ICW_ON_CHIP_CHIP_HIT", - "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip Cache with Chip HP Hit", + "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip L2-Cache with Chip HP Hit", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Chip Level-2 cache using chip level horizontal persistence, Chip-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "176", "EventName": "ICW_ON_CHIP_DRAWER_HIT", - "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip Cache with Drawer HP Hit", + "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip L2-Cache with Drawer HP Hit", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Chip level 2 cache using drawer level horizontal persistence, Drawer-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "177", "EventName": "ICW_ON_MODULE", - "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Module Cache", + "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Module L2-Cache", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Module Level-2 cache." }, { "Unit": "CPU-M-CF", "EventCode": "178", "EventName": "ICW_ON_DRAWER", - "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Drawer Cache", + "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Drawer L2-Cache", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced an On-Drawer Level-2 cache." }, { "Unit": "CPU-M-CF", "EventCode": "179", "EventName": "ICW_OFF_DRAWER", - "BriefDescription": "Directory Write Level 1 Instruction Cache from Off-Drawer Cache", + "BriefDescription": "Directory Write Level 1 Instruction Cache from Off-Drawer L2-Cache", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced an Off-Drawer Level-2 cache." }, { |