When HP laptop with AD1981 codec is suspended and the docking-station
is connected before the resume, the outputs get confused, and wrongly
routed still to the speaker. This is because of a change in 2.6.34-rc1
ea52bf260ecbb175339af3178c15788df21b7516
ALSA: hda: Add powerdown for Analog Devices HDA codecs
The problem was the added resume callback that doesn't consider the
modified init hook. The fix is simply remove the resume callback here
and make the resume normally. This doesn't change any behavior intended
in the commit above (for shutting down the sound at suspend) but only
fixes the resume.
Reported-and-tested-by: Frans Pop <elendil@planet.nl>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
Diffstat (limited to 'sound/pci')
-rw-r--r-- | sound/pci/hda/patch_analog.c | 9 |
1 files changed, 0 insertions, 9 deletions
diff --git a/sound/pci/hda/patch_analog.c b/sound/pci/hda/patch_analog.c index af34606c30c3..e9fdfc4b1c57 100644 --- a/sound/pci/hda/patch_analog.c +++ b/sound/pci/hda/patch_analog.c @@ -519,14 +519,6 @@ static int ad198x_suspend(struct hda_codec *codec, pm_message_t state) ad198x_power_eapd(codec); return 0; } - -static int ad198x_resume(struct hda_codec *codec) -{ - ad198x_init(codec); - snd_hda_codec_resume_amp(codec); - snd_hda_codec_resume_cache(codec); - return 0; -} #endif static struct hda_codec_ops ad198x_patch_ops = { @@ -539,7 +531,6 @@ static struct hda_codec_ops ad198x_patch_ops = { #endif #ifdef SND_HDA_NEEDS_RESUME .suspend = ad198x_suspend, - .resume = ad198x_resume, #endif .reboot_notify = ad198x_shutup, }; |