diff options
author | Phil Sutter <phil@nwl.cc> | 2022-10-05 18:07:05 +0200 |
---|---|---|
committer | Florian Westphal <fw@strlen.de> | 2022-10-12 14:08:15 +0200 |
commit | acc641ab95b66b813c1ce856c377a2bbe71e7f52 (patch) | |
tree | 4add7238511a0af8eea9fe77892887b0cb0bb2a0 /net | |
parent | 6e31ce831c63bd7aec8ff9cc2a6d50ee8c4d4e04 (diff) |
netfilter: rpfilter/fib: Populate flowic_l3mdev field
Use the introduced field for correct operation with VRF devices instead
of conditionally overwriting flowic_oif. This is a partial revert of
commit b575b24b8eee3 ("netfilter: Fix rpfilter dropping vrf packets by
mistake"), implementing a simpler solution.
Signed-off-by: Phil Sutter <phil@nwl.cc>
Reviewed-by: David Ahern <dsahern@kernel.org>
Reviewed-by: Guillaume Nault <gnault@redhat.com>
Signed-off-by: Florian Westphal <fw@strlen.de>
Diffstat (limited to 'net')
-rw-r--r-- | net/ipv4/netfilter/ipt_rpfilter.c | 2 | ||||
-rw-r--r-- | net/ipv4/netfilter/nft_fib_ipv4.c | 2 | ||||
-rw-r--r-- | net/ipv6/netfilter/ip6t_rpfilter.c | 9 | ||||
-rw-r--r-- | net/ipv6/netfilter/nft_fib_ipv6.c | 5 |
4 files changed, 7 insertions, 11 deletions
diff --git a/net/ipv4/netfilter/ipt_rpfilter.c b/net/ipv4/netfilter/ipt_rpfilter.c index 8183bbcabb4a..ff85db52b2e5 100644 --- a/net/ipv4/netfilter/ipt_rpfilter.c +++ b/net/ipv4/netfilter/ipt_rpfilter.c @@ -77,7 +77,7 @@ static bool rpfilter_mt(const struct sk_buff *skb, struct xt_action_param *par) flow.flowi4_mark = info->flags & XT_RPFILTER_VALID_MARK ? skb->mark : 0; flow.flowi4_tos = iph->tos & IPTOS_RT_MASK; flow.flowi4_scope = RT_SCOPE_UNIVERSE; - flow.flowi4_oif = l3mdev_master_ifindex_rcu(xt_in(par)); + flow.flowi4_l3mdev = l3mdev_master_ifindex_rcu(xt_in(par)); return rpfilter_lookup_reverse(xt_net(par), &flow, xt_in(par), info->flags) ^ invert; } diff --git a/net/ipv4/netfilter/nft_fib_ipv4.c b/net/ipv4/netfilter/nft_fib_ipv4.c index 7ade04ff972d..e886147eed11 100644 --- a/net/ipv4/netfilter/nft_fib_ipv4.c +++ b/net/ipv4/netfilter/nft_fib_ipv4.c @@ -84,7 +84,7 @@ void nft_fib4_eval(const struct nft_expr *expr, struct nft_regs *regs, oif = NULL; if (priv->flags & NFTA_FIB_F_IIF) - fl4.flowi4_oif = l3mdev_master_ifindex_rcu(oif); + fl4.flowi4_l3mdev = l3mdev_master_ifindex_rcu(oif); if (nft_hook(pkt) == NF_INET_PRE_ROUTING && nft_fib_is_loopback(pkt->skb, nft_in(pkt))) { diff --git a/net/ipv6/netfilter/ip6t_rpfilter.c b/net/ipv6/netfilter/ip6t_rpfilter.c index d800801a5dd2..69d86b040a6a 100644 --- a/net/ipv6/netfilter/ip6t_rpfilter.c +++ b/net/ipv6/netfilter/ip6t_rpfilter.c @@ -37,6 +37,7 @@ static bool rpfilter_lookup_reverse6(struct net *net, const struct sk_buff *skb, bool ret = false; struct flowi6 fl6 = { .flowi6_iif = LOOPBACK_IFINDEX, + .flowi6_l3mdev = l3mdev_master_ifindex_rcu(dev), .flowlabel = (* (__be32 *) iph) & IPV6_FLOWINFO_MASK, .flowi6_proto = iph->nexthdr, .daddr = iph->saddr, @@ -55,9 +56,7 @@ static bool rpfilter_lookup_reverse6(struct net *net, const struct sk_buff *skb, if (rpfilter_addr_linklocal(&iph->saddr)) { lookup_flags |= RT6_LOOKUP_F_IFACE; fl6.flowi6_oif = dev->ifindex; - /* Set flowi6_oif for vrf devices to lookup route in l3mdev domain. */ - } else if (netif_is_l3_master(dev) || netif_is_l3_slave(dev) || - (flags & XT_RPFILTER_LOOSE) == 0) + } else if ((flags & XT_RPFILTER_LOOSE) == 0) fl6.flowi6_oif = dev->ifindex; rt = (void *)ip6_route_lookup(net, &fl6, skb, lookup_flags); @@ -72,9 +71,7 @@ static bool rpfilter_lookup_reverse6(struct net *net, const struct sk_buff *skb, goto out; } - if (rt->rt6i_idev->dev == dev || - l3mdev_master_ifindex_rcu(rt->rt6i_idev->dev) == dev->ifindex || - (flags & XT_RPFILTER_LOOSE)) + if (rt->rt6i_idev->dev == dev || (flags & XT_RPFILTER_LOOSE)) ret = true; out: ip6_rt_put(rt); diff --git a/net/ipv6/netfilter/nft_fib_ipv6.c b/net/ipv6/netfilter/nft_fib_ipv6.c index 1d7e520d9966..91faac610e03 100644 --- a/net/ipv6/netfilter/nft_fib_ipv6.c +++ b/net/ipv6/netfilter/nft_fib_ipv6.c @@ -41,9 +41,8 @@ static int nft_fib6_flowi_init(struct flowi6 *fl6, const struct nft_fib *priv, if (ipv6_addr_type(&fl6->daddr) & IPV6_ADDR_LINKLOCAL) { lookup_flags |= RT6_LOOKUP_F_IFACE; fl6->flowi6_oif = get_ifindex(dev ? dev : pkt->skb->dev); - } else if ((priv->flags & NFTA_FIB_F_IIF) && - (netif_is_l3_master(dev) || netif_is_l3_slave(dev))) { - fl6->flowi6_oif = dev->ifindex; + } else if (priv->flags & NFTA_FIB_F_IIF) { + fl6->flowi6_l3mdev = l3mdev_master_ifindex_rcu(dev); } if (ipv6_addr_type(&fl6->saddr) & IPV6_ADDR_UNICAST) |