diff options
author | Andreas Herrmann <andreas.herrmann3@amd.com> | 2009-08-18 13:01:11 +0200 |
---|---|---|
committer | Ingo Molnar <mingo@elte.hu> | 2009-08-18 18:35:44 +0200 |
commit | 0601a88d8fa4508eaa49a6d96c6685e1dece38e3 (patch) | |
tree | 986cc76c135f45817a56291b8148bafac304bf09 /kernel/sched.c | |
parent | de616e36c700dc312d9021dd75f769c463f85122 (diff) |
sched: Separate out build of NUMA sched groups from __build_sched_domains
... to further strip down __build_sched_domains().
Signed-off-by: Andreas Herrmann <andreas.herrmann3@amd.com>
Cc: Peter Zijlstra <peterz@infradead.org>
LKML-Reference: <20090818110111.GL29515@alberich.amd.com>
Signed-off-by: Ingo Molnar <mingo@elte.hu>
Diffstat (limited to 'kernel/sched.c')
-rw-r--r-- | kernel/sched.c | 130 |
1 files changed, 67 insertions, 63 deletions
diff --git a/kernel/sched.c b/kernel/sched.c index 52c1953bc41d..c1ce884a0163 100644 --- a/kernel/sched.c +++ b/kernel/sched.c @@ -8246,6 +8246,71 @@ static void init_numa_sched_groups_power(struct sched_group *group_head) sg = sg->next; } while (sg != group_head); } + +static int build_numa_sched_groups(struct s_data *d, + const struct cpumask *cpu_map, int num) +{ + struct sched_domain *sd; + struct sched_group *sg, *prev; + int n, j; + + cpumask_clear(d->covered); + cpumask_and(d->nodemask, cpumask_of_node(num), cpu_map); + if (cpumask_empty(d->nodemask)) { + d->sched_group_nodes[num] = NULL; + goto out; + } + + sched_domain_node_span(num, d->domainspan); + cpumask_and(d->domainspan, d->domainspan, cpu_map); + + sg = kmalloc_node(sizeof(struct sched_group) + cpumask_size(), + GFP_KERNEL, num); + if (!sg) { + printk(KERN_WARNING "Can not alloc domain group for node %d\n", + num); + return -ENOMEM; + } + d->sched_group_nodes[num] = sg; + + for_each_cpu(j, d->nodemask) { + sd = &per_cpu(node_domains, j).sd; + sd->groups = sg; + } + + sg->__cpu_power = 0; + cpumask_copy(sched_group_cpus(sg), d->nodemask); + sg->next = sg; + cpumask_or(d->covered, d->covered, d->nodemask); + + prev = sg; + for (j = 0; j < nr_node_ids; j++) { + n = (num + j) % nr_node_ids; + cpumask_complement(d->notcovered, d->covered); + cpumask_and(d->tmpmask, d->notcovered, cpu_map); + cpumask_and(d->tmpmask, d->tmpmask, d->domainspan); + if (cpumask_empty(d->tmpmask)) + break; + cpumask_and(d->tmpmask, d->tmpmask, cpumask_of_node(n)); + if (cpumask_empty(d->tmpmask)) + continue; + sg = kmalloc_node(sizeof(struct sched_group) + cpumask_size(), + GFP_KERNEL, num); + if (!sg) { + printk(KERN_WARNING + "Can not alloc domain group for node %d\n", j); + return -ENOMEM; + } + sg->__cpu_power = 0; + cpumask_copy(sched_group_cpus(sg), d->tmpmask); + sg->next = prev->next; + cpumask_or(d->covered, d->covered, d->tmpmask); + prev->next = sg; + prev = sg; + } +out: + return 0; +} #endif /* CONFIG_NUMA */ #ifdef CONFIG_NUMA @@ -8652,70 +8717,9 @@ static int __build_sched_domains(const struct cpumask *cpu_map, if (d.sd_allnodes) build_sched_groups(&d, SD_LV_ALLNODES, cpu_map, 0); - for (i = 0; i < nr_node_ids; i++) { - /* Set up node groups */ - struct sched_group *sg, *prev; - int j; - - cpumask_clear(d.covered); - cpumask_and(d.nodemask, cpumask_of_node(i), cpu_map); - if (cpumask_empty(d.nodemask)) { - d.sched_group_nodes[i] = NULL; - continue; - } - - sched_domain_node_span(i, d.domainspan); - cpumask_and(d.domainspan, d.domainspan, cpu_map); - - sg = kmalloc_node(sizeof(struct sched_group) + cpumask_size(), - GFP_KERNEL, i); - if (!sg) { - printk(KERN_WARNING "Can not alloc domain group for " - "node %d\n", i); + for (i = 0; i < nr_node_ids; i++) + if (build_numa_sched_groups(&d, cpu_map, i)) goto error; - } - d.sched_group_nodes[i] = sg; - for_each_cpu(j, d.nodemask) { - struct sched_domain *sd; - - sd = &per_cpu(node_domains, j).sd; - sd->groups = sg; - } - sg->__cpu_power = 0; - cpumask_copy(sched_group_cpus(sg), d.nodemask); - sg->next = sg; - cpumask_or(d.covered, d.covered, d.nodemask); - prev = sg; - - for (j = 0; j < nr_node_ids; j++) { - int n = (i + j) % nr_node_ids; - - cpumask_complement(d.notcovered, d.covered); - cpumask_and(d.tmpmask, d.notcovered, cpu_map); - cpumask_and(d.tmpmask, d.tmpmask, d.domainspan); - if (cpumask_empty(d.tmpmask)) - break; - - cpumask_and(d.tmpmask, d.tmpmask, cpumask_of_node(n)); - if (cpumask_empty(d.tmpmask)) - continue; - - sg = kmalloc_node(sizeof(struct sched_group) + - cpumask_size(), - GFP_KERNEL, i); - if (!sg) { - printk(KERN_WARNING - "Can not alloc domain group for node %d\n", j); - goto error; - } - sg->__cpu_power = 0; - cpumask_copy(sched_group_cpus(sg), d.tmpmask); - sg->next = prev->next; - cpumask_or(d.covered, d.covered, d.tmpmask); - prev->next = sg; - prev = sg; - } - } #endif /* Calculate CPU power for physical packages and nodes */ |