diff options
author | Michael Hennerich <michael.hennerich@analog.com> | 2012-07-06 10:44:19 -0700 |
---|---|---|
committer | Dmitry Torokhov <dmitry.torokhov@gmail.com> | 2012-07-06 19:12:26 -0700 |
commit | 6680884a44207efe8ef6bc56b1c932cce2b89994 (patch) | |
tree | aca3138305a44c4766e19c69d4da43fc16e810d4 /include/linux/spi | |
parent | f2bb26b9b7652287719f08f080c09c2d7ddcf6b5 (diff) |
Input: ad7879 - add option to correct xy axis
Sebastian Zenker reported that driver swaps x and y samples when the
touchscreen leads are connected in accordance with the datasheet
specification. Transposed axis can be typically corrected by touch
screen calibration however this bug also negatively influences touch
pressure measurements.
Add an option to correct x and y axis.
Signed-off-by: Michael Hennerich <michael.hennerich@analog.com>
Reported-and-tested-by: Sebastian Zenker <sebastian.zenker@gmx.de>
Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
Diffstat (limited to 'include/linux/spi')
-rw-r--r-- | include/linux/spi/ad7879.h | 2 |
1 files changed, 2 insertions, 0 deletions
diff --git a/include/linux/spi/ad7879.h b/include/linux/spi/ad7879.h index 6334cee1a3be..58368be0b4c0 100644 --- a/include/linux/spi/ad7879.h +++ b/include/linux/spi/ad7879.h @@ -12,6 +12,8 @@ struct ad7879_platform_data { u16 y_min, y_max; u16 pressure_min, pressure_max; + bool swap_xy; /* swap x and y axes */ + /* [0..255] 0=OFF Starts at 1=550us and goes * all the way to 9.440ms in steps of 35us. */ |