diff options
author | Hans de Goede <hdegoede@redhat.com> | 2022-11-28 10:28:52 +0100 |
---|---|---|
committer | Sebastian Reichel <sebastian.reichel@collabora.com> | 2023-01-03 00:04:26 +0100 |
commit | 4413f9e9138fe4c50db80596635a1f7f1e8bfa6a (patch) | |
tree | 724090ef7706214afcd8c5000529726c2e5aa44d /drivers/power/supply/bq25890_charger.c | |
parent | c688e0c436cb5292285a193134346fcdaaa3a56d (diff) |
power: supply: bq25890: Fix setting of F_CONV_RATE rate when disabling HiZ mode
The recent "power: supply: bq25890: Add HiZ mode support" change
leaves F_CONV_RATE rate unset when disabling HiZ mode (setting
POWER_SUPPLY_PROP_ONLINE to 1) while a charger is connected.
Separate the resetting HiZ mode (when necessary because of a charger
(re)plug event) into its own "if {}" block which runs first.
And fix the setting of F_CONV_RATE rate by adding helper variables for
the old and new F_CONV_RATE state which check both the online and hiz bits
and then compare the helper variables to see if a F_CONV_RATE update is
necessary.
Reviewed-by: Marek Vasut <marex@denx.de>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Diffstat (limited to 'drivers/power/supply/bq25890_charger.c')
-rw-r--r-- | drivers/power/supply/bq25890_charger.c | 41 |
1 files changed, 17 insertions, 24 deletions
diff --git a/drivers/power/supply/bq25890_charger.c b/drivers/power/supply/bq25890_charger.c index f5fa39dca832..0d188c0d94ff 100644 --- a/drivers/power/supply/bq25890_charger.c +++ b/drivers/power/supply/bq25890_charger.c @@ -795,6 +795,7 @@ static int bq25890_get_chip_state(struct bq25890_device *bq, static irqreturn_t __bq25890_handle_irq(struct bq25890_device *bq) { + bool adc_conv_rate, new_adc_conv_rate; struct bq25890_state new_state; int ret; @@ -805,33 +806,25 @@ static irqreturn_t __bq25890_handle_irq(struct bq25890_device *bq) if (!memcmp(&bq->state, &new_state, sizeof(new_state))) return IRQ_NONE; - /* power removed or HiZ */ - if ((!new_state.online || new_state.hiz) && bq->state.online) { - /* disable ADC */ - ret = bq25890_field_write(bq, F_CONV_RATE, 0); + /* + * Restore HiZ bit in case it was set by user. The chip does not retain + * this bit on cable replug, hence the bit must be reset manually here. + */ + if (new_state.online && !bq->state.online && bq->force_hiz) { + ret = bq25890_field_write(bq, F_EN_HIZ, bq->force_hiz); if (ret < 0) goto error; - } else if (new_state.online && !bq->state.online) { - /* - * Restore HiZ bit in case it was set by user. - * The chip does not retain this bit once the - * cable is re-plugged, hence the bit must be - * reset manually here. - */ - if (bq->force_hiz) { - ret = bq25890_field_write(bq, F_EN_HIZ, bq->force_hiz); - if (ret < 0) - goto error; - new_state.hiz = 1; - } + new_state.hiz = 1; + } - if (!new_state.hiz) { - /* power inserted and not HiZ */ - /* enable ADC, to have control of charge current/voltage */ - ret = bq25890_field_write(bq, F_CONV_RATE, 1); - if (ret < 0) - goto error; - } + /* Should period ADC sampling be enabled? */ + adc_conv_rate = bq->state.online && !bq->state.hiz; + new_adc_conv_rate = new_state.online && !new_state.hiz; + + if (new_adc_conv_rate != adc_conv_rate) { + ret = bq25890_field_write(bq, F_CONV_RATE, new_adc_conv_rate); + if (ret < 0) + goto error; } bq->state = new_state; |