diff options
author | Rafael J. Wysocki <rafael.j.wysocki@intel.com> | 2018-01-18 02:52:42 +0100 |
---|---|---|
committer | Rafael J. Wysocki <rafael.j.wysocki@intel.com> | 2018-01-18 02:52:42 +0100 |
commit | f06970f4b03dffeb9831a8ad605db3c85a55aca1 (patch) | |
tree | a4477a4878350d63e3399e7f0d57d64e26065f09 /drivers/cpufreq | |
parent | 343a8d17fa8d6dd97f408e8fedbcef12073f3774 (diff) | |
parent | ac89c400ebb146604e718b3fa168c15592e73a8c (diff) |
Merge branch 'pm-cpufreq-thermal' into pm-cpufreq
* pm-cpufreq-thermal:
cpu_cooling: Remove static-power related documentation
cpu_cooling: Drop static-power related stuff
cpu_cooling: Keep only one of_cpufreq*cooling_register() helper
cpu_cooling: Remove unused cpufreq_power_cooling_register()
cpu_cooling: Make of_cpufreq_power_cooling_register() parse DT
Diffstat (limited to 'drivers/cpufreq')
-rw-r--r-- | drivers/cpufreq/arm_big_little.c | 23 | ||||
-rw-r--r-- | drivers/cpufreq/cpufreq-dt.c | 27 | ||||
-rw-r--r-- | drivers/cpufreq/mediatek-cpufreq.c | 22 | ||||
-rw-r--r-- | drivers/cpufreq/qoriq-cpufreq.c | 14 |
4 files changed, 4 insertions, 82 deletions
diff --git a/drivers/cpufreq/arm_big_little.c b/drivers/cpufreq/arm_big_little.c index 65ec5f01aa8d..c56b57dcfda5 100644 --- a/drivers/cpufreq/arm_big_little.c +++ b/drivers/cpufreq/arm_big_little.c @@ -526,34 +526,13 @@ static int bL_cpufreq_exit(struct cpufreq_policy *policy) static void bL_cpufreq_ready(struct cpufreq_policy *policy) { - struct device *cpu_dev = get_cpu_device(policy->cpu); int cur_cluster = cpu_to_cluster(policy->cpu); - struct device_node *np; /* Do not register a cpu_cooling device if we are in IKS mode */ if (cur_cluster >= MAX_CLUSTERS) return; - np = of_node_get(cpu_dev->of_node); - if (WARN_ON(!np)) - return; - - if (of_find_property(np, "#cooling-cells", NULL)) { - u32 power_coefficient = 0; - - of_property_read_u32(np, "dynamic-power-coefficient", - &power_coefficient); - - cdev[cur_cluster] = of_cpufreq_power_cooling_register(np, - policy, power_coefficient, NULL); - if (IS_ERR(cdev[cur_cluster])) { - dev_err(cpu_dev, - "running cpufreq without cooling device: %ld\n", - PTR_ERR(cdev[cur_cluster])); - cdev[cur_cluster] = NULL; - } - } - of_node_put(np); + cdev[cur_cluster] = of_cpufreq_cooling_register(policy); } static struct cpufreq_driver bL_cpufreq_driver = { diff --git a/drivers/cpufreq/cpufreq-dt.c b/drivers/cpufreq/cpufreq-dt.c index 545946ad0752..de3d104c25d7 100644 --- a/drivers/cpufreq/cpufreq-dt.c +++ b/drivers/cpufreq/cpufreq-dt.c @@ -319,33 +319,8 @@ static int cpufreq_exit(struct cpufreq_policy *policy) static void cpufreq_ready(struct cpufreq_policy *policy) { struct private_data *priv = policy->driver_data; - struct device_node *np = of_node_get(priv->cpu_dev->of_node); - if (WARN_ON(!np)) - return; - - /* - * For now, just loading the cooling device; - * thermal DT code takes care of matching them. - */ - if (of_find_property(np, "#cooling-cells", NULL)) { - u32 power_coefficient = 0; - - of_property_read_u32(np, "dynamic-power-coefficient", - &power_coefficient); - - priv->cdev = of_cpufreq_power_cooling_register(np, - policy, power_coefficient, NULL); - if (IS_ERR(priv->cdev)) { - dev_err(priv->cpu_dev, - "running cpufreq without cooling device: %ld\n", - PTR_ERR(priv->cdev)); - - priv->cdev = NULL; - } - } - - of_node_put(np); + priv->cdev = of_cpufreq_cooling_register(policy); } static struct cpufreq_driver dt_cpufreq_driver = { diff --git a/drivers/cpufreq/mediatek-cpufreq.c b/drivers/cpufreq/mediatek-cpufreq.c index b783919f063d..8c04dddd3c28 100644 --- a/drivers/cpufreq/mediatek-cpufreq.c +++ b/drivers/cpufreq/mediatek-cpufreq.c @@ -310,28 +310,8 @@ static int mtk_cpufreq_set_target(struct cpufreq_policy *policy, static void mtk_cpufreq_ready(struct cpufreq_policy *policy) { struct mtk_cpu_dvfs_info *info = policy->driver_data; - struct device_node *np = of_node_get(info->cpu_dev->of_node); - u32 capacitance = 0; - if (WARN_ON(!np)) - return; - - if (of_find_property(np, "#cooling-cells", NULL)) { - of_property_read_u32(np, DYNAMIC_POWER, &capacitance); - - info->cdev = of_cpufreq_power_cooling_register(np, - policy, capacitance, NULL); - - if (IS_ERR(info->cdev)) { - dev_err(info->cpu_dev, - "running cpufreq without cooling device: %ld\n", - PTR_ERR(info->cdev)); - - info->cdev = NULL; - } - } - - of_node_put(np); + info->cdev = of_cpufreq_cooling_register(policy); } static int mtk_cpu_dvfs_info_init(struct mtk_cpu_dvfs_info *info, int cpu) diff --git a/drivers/cpufreq/qoriq-cpufreq.c b/drivers/cpufreq/qoriq-cpufreq.c index 4ada55b8856e..0562761a3dec 100644 --- a/drivers/cpufreq/qoriq-cpufreq.c +++ b/drivers/cpufreq/qoriq-cpufreq.c @@ -275,20 +275,8 @@ static int qoriq_cpufreq_target(struct cpufreq_policy *policy, static void qoriq_cpufreq_ready(struct cpufreq_policy *policy) { struct cpu_data *cpud = policy->driver_data; - struct device_node *np = of_get_cpu_node(policy->cpu, NULL); - if (of_find_property(np, "#cooling-cells", NULL)) { - cpud->cdev = of_cpufreq_cooling_register(np, policy); - - if (IS_ERR(cpud->cdev) && PTR_ERR(cpud->cdev) != -ENOSYS) { - pr_err("cpu%d is not running as cooling device: %ld\n", - policy->cpu, PTR_ERR(cpud->cdev)); - - cpud->cdev = NULL; - } - } - - of_node_put(np); + cpud->cdev = of_cpufreq_cooling_register(policy); } static struct cpufreq_driver qoriq_cpufreq_driver = { |