diff options
author | Roland Stigge <stigge@antcom.de> | 2012-06-14 16:16:16 +0200 |
---|---|---|
committer | Roland Stigge <stigge@antcom.de> | 2012-06-14 16:16:16 +0200 |
commit | ba225a0ea225902501487a2c9f620c26dce1cee6 (patch) | |
tree | c0252a6756cd03e3bb74950e1b46011aefa88152 /arch/arm/mach-lpc32xx | |
parent | b27f48227c59754e1c881bd8e2b327ac02fe17b6 (diff) |
ARM: LPC32xx: Remove SLC controller initialization from platform init
Since we now support two MTD NAND controllers (MLC and SLC) for LPC32xx via DT,
we don't initialize the SLC controller statically anymore, but do it via the
clock setup (see previous patch).
Signed-off-by: Roland Stigge <stigge@antcom.de>
Tested-by: Alexandre Pereira da Silva <aletes.xgr@gmail.com>
Diffstat (limited to 'arch/arm/mach-lpc32xx')
-rw-r--r-- | arch/arm/mach-lpc32xx/phy3250.c | 4 |
1 files changed, 0 insertions, 4 deletions
diff --git a/arch/arm/mach-lpc32xx/phy3250.c b/arch/arm/mach-lpc32xx/phy3250.c index 540106cdb9ec..42a078eb1665 100644 --- a/arch/arm/mach-lpc32xx/phy3250.c +++ b/arch/arm/mach-lpc32xx/phy3250.c @@ -241,10 +241,6 @@ static void __init lpc3250_machine_init(void) { u32 tmp; - /* Setup SLC NAND controller muxing */ - __raw_writel(LPC32XX_CLKPWR_NANDCLK_SEL_SLC, - LPC32XX_CLKPWR_NAND_CLK_CTRL); - /* Setup LCD muxing to RGB565 */ tmp = __raw_readl(LPC32XX_CLKPWR_LCDCLK_CTRL) & ~(LPC32XX_CLKPWR_LCDCTRL_LCDTYPE_MSK | |