authorJiawen Wu <jiawenwu@trustnetic.com>2023-08-23 14:19:29 +0800
committerDavid S. Miller <davem@davemloft.net>2023-08-25 07:42:58 +0100
commitf629acc6f21043fdc80ae93cdafa6713888db0fd (patch)
tree653643f82483cc090bee727d2f73e65aaf83e80d /MAINTAINERS
parentd55595f04dcc8bd6f6ff33f451dda8de3f1232da (diff)
net: pcs: xpcs: support to switch mode for Wangxun NICs
According to chapter 6 of DesignWare Cores Ethernet PCS (version 3.20a) and custom design manual, add a configuration flow for switching interface mode. If the interface changes, the following setting is required: 1. wait VR_XS_PCS_DIG_STS bit(4, 2) [PSEQ_STATE] = 100b (Power-Good) 2. write SR_XS_PCS_CTRL2 to select various PCS type 3. write SR_PMA_CTRL1 and/or SR_XS_PCS_CTRL1 for link speed 4. program PMA registers 5. write VR_XS_PCS_DIG_CTRL1 bit(15) [VR_RST] = 1b (Vendor-Specific Soft Reset) 6. wait for VR_XS_PCS_DIG_CTRL1 bit(15) [VR_RST] to get cleared Only 10GBASE-R/SGMII/1000BASE-X modes are planned for the current Wangxun devices. And there is a quirk for Wangxun devices to switch mode although the interface in phylink state has not changed, since PCS will change to default 10GBASE-R when the ethernet driver(txgbe) do LAN reset. Signed-off-by: Jiawen Wu <jiawenwu@trustnetic.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'MAINTAINERS')
-rw-r--r--MAINTAINERS1
1 files changed, 1 insertions, 0 deletions
diff --git a/MAINTAINERS b/MAINTAINERS
index dfc2ba0c20f3..5f527a9ae4b2 100644
--- a/MAINTAINERS
+++ b/MAINTAINERS
@@ -22925,6 +22925,7 @@ S: Maintained
W: https://www.net-swift.com
F: Documentation/networking/device_drivers/ethernet/wangxun/*
F: drivers/net/ethernet/wangxun/
+F: drivers/net/pcs/pcs-xpcs-wx.c
WATCHDOG DEVICE DRIVERS
M: Wim Van Sebroeck <wim@linux-watchdog.org>