summaryrefslogtreecommitdiff
path: root/Documentation
diff options
context:
space:
mode:
authorMariusz Bialonczyk <manio@skyboo.net>2018-07-05 06:51:36 +0200
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2018-07-07 17:27:13 +0200
commitc7e5a5b4f0371dac0888e2be7c59273d8e4c013f (patch)
tree7fc22a28bf8c6e0fa1f4f2c2f2927f7e545ecdf4 /Documentation
parent7b4bcbcdb2a9c16ec8d83f43c04c4dd4db0df032 (diff)
w1: fix w1_ds2438 documentation
The previous documentation was wrongly stating about the order of magnitude of CONVERT_V result files contents (vad, vdd). This commit is correcting this. Reported-by: Adam Stolarczyk <adam@stolarczyk.net.pl> Signed-off-by: Mariusz Bialonczyk <manio@skyboo.net> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/w1/slaves/w1_ds24382
1 files changed, 1 insertions, 1 deletions
diff --git a/Documentation/w1/slaves/w1_ds2438 b/Documentation/w1/slaves/w1_ds2438
index b99f3674c5b4..e64f65a09387 100644
--- a/Documentation/w1/slaves/w1_ds2438
+++ b/Documentation/w1/slaves/w1_ds2438
@@ -60,4 +60,4 @@ vad: general purpose A/D input (VAD)
vdd: battery input (VDD)
After the voltage conversion the value is returned as decimal ASCII.
-Note: The value is in mV, so to get a volts the value has to be divided by 10.
+Note: To get a volts the value has to be divided by 100.