diff options
author | Paul Mackerras <paulus@samba.org> | 2007-09-20 10:09:27 +1000 |
---|---|---|
committer | Paul Mackerras <paulus@samba.org> | 2007-09-20 10:09:27 +1000 |
commit | 0ce49a3945474fc942ec37c0c0efece60f592f80 (patch) | |
tree | f42b821b2d9e2d8775bc22f56d444c2cc7b7b7dd /Documentation | |
parent | 9e4859ef5462193643fd2b3c8ffb298e5a4a4319 (diff) | |
parent | a88a8eff1e6e32d3288986a9d36c6a449c032d3a (diff) |
Merge branch 'linux-2.6'
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/ManagementStyle | 2 | ||||
-rw-r--r-- | Documentation/feature-removal-schedule.txt | 8 | ||||
-rw-r--r-- | Documentation/kernel-parameters.txt | 3 | ||||
-rw-r--r-- | Documentation/networking/00-INDEX | 3 | ||||
-rw-r--r-- | Documentation/networking/sk98lin.txt | 568 | ||||
-rw-r--r-- | Documentation/thinkpad-acpi.txt | 96 | ||||
-rw-r--r-- | Documentation/video4linux/cx2341x/fw-encoder-api.txt | 4 |
7 files changed, 660 insertions, 24 deletions
diff --git a/Documentation/ManagementStyle b/Documentation/ManagementStyle index cbbebfb51ffe..49a8efa5afeb 100644 --- a/Documentation/ManagementStyle +++ b/Documentation/ManagementStyle @@ -166,7 +166,7 @@ To solve this problem, you really only have two options: The option of being unfailingly polite really doesn't exist. Nobody will trust somebody who is so clearly hiding his true character. -(*) Paul Simon sang "Fifty Ways to Lose Your Lover", because quite +(*) Paul Simon sang "Fifty Ways to Leave Your Lover", because quite frankly, "A Million Ways to Tell a Developer He Is a D*ckhead" doesn't scan nearly as well. But I'm sure he thought about it. diff --git a/Documentation/feature-removal-schedule.txt b/Documentation/feature-removal-schedule.txt index b9a3fdc1cc5a..00928d2ecfb2 100644 --- a/Documentation/feature-removal-schedule.txt +++ b/Documentation/feature-removal-schedule.txt @@ -298,3 +298,11 @@ Why: All mthca hardware also supports MSI-X, which provides Who: Roland Dreier <rolandd@cisco.com> --------------------------- + +What: sk98lin network driver +When: Feburary 2008 +Why: In kernel tree version of driver is unmaintained. Sk98lin driver + replaced by the skge driver. +Who: Stephen Hemminger <shemminger@linux-foundation.org> + +--------------------------- diff --git a/Documentation/kernel-parameters.txt b/Documentation/kernel-parameters.txt index b41cde31d112..4d175c751246 100644 --- a/Documentation/kernel-parameters.txt +++ b/Documentation/kernel-parameters.txt @@ -468,9 +468,6 @@ and is between 256 and 4096 characters. It is defined in the file Format: <first_slot>,<last_slot>,<port>,<enum_bit>[,<debug>] - cpia_pp= [HW,PPT] - Format: { parport<nr> | auto | none } - crashkernel=nn[KMG]@ss[KMG] [KNL] Reserve a chunk of physical memory to hold a kernel to switch to with kexec on panic. diff --git a/Documentation/networking/00-INDEX b/Documentation/networking/00-INDEX index d63f480afb74..153d84d281e6 100644 --- a/Documentation/networking/00-INDEX +++ b/Documentation/networking/00-INDEX @@ -96,6 +96,9 @@ routing.txt - the new routing mechanism shaper.txt - info on the module that can shape/limit transmitted traffic. +sk98lin.txt + - Marvell Yukon Chipset / SysKonnect SK-98xx compliant Gigabit + Ethernet Adapter family driver info skfp.txt - SysKonnect FDDI (SK-5xxx, Compaq Netelligent) driver info. smc9.txt diff --git a/Documentation/networking/sk98lin.txt b/Documentation/networking/sk98lin.txt new file mode 100644 index 000000000000..8590a954df1d --- /dev/null +++ b/Documentation/networking/sk98lin.txt @@ -0,0 +1,568 @@ +(C)Copyright 1999-2004 Marvell(R). +All rights reserved +=========================================================================== + +sk98lin.txt created 13-Feb-2004 + +Readme File for sk98lin v6.23 +Marvell Yukon/SysKonnect SK-98xx Gigabit Ethernet Adapter family driver for LINUX + +This file contains + 1 Overview + 2 Required Files + 3 Installation + 3.1 Driver Installation + 3.2 Inclusion of adapter at system start + 4 Driver Parameters + 4.1 Per-Port Parameters + 4.2 Adapter Parameters + 5 Large Frame Support + 6 VLAN and Link Aggregation Support (IEEE 802.1, 802.1q, 802.3ad) + 7 Troubleshooting + +=========================================================================== + + +1 Overview +=========== + +The sk98lin driver supports the Marvell Yukon and SysKonnect +SK-98xx/SK-95xx compliant Gigabit Ethernet Adapter on Linux. It has +been tested with Linux on Intel/x86 machines. +*** + + +2 Required Files +================= + +The linux kernel source. +No additional files required. +*** + + +3 Installation +=============== + +It is recommended to download the latest version of the driver from the +SysKonnect web site www.syskonnect.com. If you have downloaded the latest +driver, the Linux kernel has to be patched before the driver can be +installed. For details on how to patch a Linux kernel, refer to the +patch.txt file. + +3.1 Driver Installation +------------------------ + +The following steps describe the actions that are required to install +the driver and to start it manually. These steps should be carried +out for the initial driver setup. Once confirmed to be ok, they can +be included in the system start. + +NOTE 1: To perform the following tasks you need 'root' access. + +NOTE 2: In case of problems, please read the section "Troubleshooting" + below. + +The driver can either be integrated into the kernel or it can be compiled +as a module. Select the appropriate option during the kernel +configuration. + +Compile/use the driver as a module +---------------------------------- +To compile the driver, go to the directory /usr/src/linux and +execute the command "make menuconfig" or "make xconfig" and proceed as +follows: + +To integrate the driver permanently into the kernel, proceed as follows: + +1. Select the menu "Network device support" and then "Ethernet(1000Mbit)" +2. Mark "Marvell Yukon Chipset / SysKonnect SK-98xx family support" + with (*) +3. Build a new kernel when the configuration of the above options is + finished. +4. Install the new kernel. +5. Reboot your system. + +To use the driver as a module, proceed as follows: + +1. Enable 'loadable module support' in the kernel. +2. For automatic driver start, enable the 'Kernel module loader'. +3. Select the menu "Network device support" and then "Ethernet(1000Mbit)" +4. Mark "Marvell Yukon Chipset / SysKonnect SK-98xx family support" + with (M) +5. Execute the command "make modules". +6. Execute the command "make modules_install". + The appropriate modules will be installed. +7. Reboot your system. + + +Load the module manually +------------------------ +To load the module manually, proceed as follows: + +1. Enter "modprobe sk98lin". +2. If a Marvell Yukon or SysKonnect SK-98xx adapter is installed in + your computer and you have a /proc file system, execute the command: + "ls /proc/net/sk98lin/" + This should produce an output containing a line with the following + format: + eth0 eth1 ... + which indicates that your adapter has been found and initialized. + + NOTE 1: If you have more than one Marvell Yukon or SysKonnect SK-98xx + adapter installed, the adapters will be listed as 'eth0', + 'eth1', 'eth2', etc. + For each adapter, repeat steps 3 and 4 below. + + NOTE 2: If you have other Ethernet adapters installed, your Marvell + Yukon or SysKonnect SK-98xx adapter will be mapped to the + next available number, e.g. 'eth1'. The mapping is executed + automatically. + The module installation message (displayed either in a system + log file or on the console) prints a line for each adapter + found containing the corresponding 'ethX'. + +3. Select an IP address and assign it to the respective adapter by + entering: + ifconfig eth0 <ip-address> + With this command, the adapter is connected to the Ethernet. + + SK-98xx Gigabit Ethernet Server Adapters: The yellow LED on the adapter + is now active, the link status LED of the primary port is active and + the link status LED of the secondary port (on dual port adapters) is + blinking (if the ports are connected to a switch or hub). + SK-98xx V2.0 Gigabit Ethernet Adapters: The link status LED is active. + In addition, you will receive a status message on the console stating + "ethX: network connection up using port Y" and showing the selected + connection parameters (x stands for the ethernet device number + (0,1,2, etc), y stands for the port name (A or B)). + + NOTE: If you are in doubt about IP addresses, ask your network + administrator for assistance. + +4. Your adapter should now be fully operational. + Use 'ping <otherstation>' to verify the connection to other computers + on your network. +5. To check the adapter configuration view /proc/net/sk98lin/[devicename]. + For example by executing: + "cat /proc/net/sk98lin/eth0" + +Unload the module +----------------- +To stop and unload the driver modules, proceed as follows: + +1. Execute the command "ifconfig eth0 down". +2. Execute the command "rmmod sk98lin". + +3.2 Inclusion of adapter at system start +----------------------------------------- + +Since a large number of different Linux distributions are +available, we are unable to describe a general installation procedure +for the driver module. +Because the driver is now integrated in the kernel, installation should +be easy, using the standard mechanism of your distribution. +Refer to the distribution's manual for installation of ethernet adapters. + +*** + +4 Driver Parameters +==================== + +Parameters can be set at the command line after the module has been +loaded with the command 'modprobe'. +In some distributions, the configuration tools are able to pass parameters +to the driver module. + +If you use the kernel module loader, you can set driver parameters +in the file /etc/modprobe.conf (or /etc/modules.conf in 2.4 or earlier). +To set the driver parameters in this file, proceed as follows: + +1. Insert a line of the form : + options sk98lin ... + For "...", the same syntax is required as described for the command + line parameters of modprobe below. +2. To activate the new parameters, either reboot your computer + or + unload and reload the driver. + The syntax of the driver parameters is: + + modprobe sk98lin parameter=value1[,value2[,value3...]] + + where value1 refers to the first adapter, value2 to the second etc. + +NOTE: All parameters are case sensitive. Write them exactly as shown + below. + +Example: +Suppose you have two adapters. You want to set auto-negotiation +on the first adapter to ON and on the second adapter to OFF. +You also want to set DuplexCapabilities on the first adapter +to FULL, and on the second adapter to HALF. +Then, you must enter: + + modprobe sk98lin AutoNeg_A=On,Off DupCap_A=Full,Half + +NOTE: The number of adapters that can be configured this way is + limited in the driver (file skge.c, constant SK_MAX_CARD_PARAM). + The current limit is 16. If you happen to install + more adapters, adjust this and recompile. + + +4.1 Per-Port Parameters +------------------------ + +These settings are available for each port on the adapter. +In the following description, '?' stands for the port for +which you set the parameter (A or B). + +Speed +----- +Parameter: Speed_? +Values: 10, 100, 1000, Auto +Default: Auto + +This parameter is used to set the speed capabilities. It is only valid +for the SK-98xx V2.0 copper adapters. +Usually, the speed is negotiated between the two ports during link +establishment. If this fails, a port can be forced to a specific setting +with this parameter. + +Auto-Negotiation +---------------- +Parameter: AutoNeg_? +Values: On, Off, Sense +Default: On + +The "Sense"-mode automatically detects whether the link partner supports +auto-negotiation or not. + +Duplex Capabilities +------------------- +Parameter: DupCap_? +Values: Half, Full, Both +Default: Both + +This parameters is only relevant if auto-negotiation for this port is +not set to "Sense". If auto-negotiation is set to "On", all three values +are possible. If it is set to "Off", only "Full" and "Half" are allowed. +This parameter is useful if your link partner does not support all +possible combinations. + +Flow Control +------------ +Parameter: FlowCtrl_? +Values: Sym, SymOrRem, LocSend, None +Default: SymOrRem + +This parameter can be used to set the flow control capabilities the +port reports during auto-negotiation. It can be set for each port +individually. +Possible modes: + -- Sym = Symmetric: both link partners are allowed to send + PAUSE frames + -- SymOrRem = SymmetricOrRemote: both or only remote partner + are allowed to send PAUSE frames + -- LocSend = LocalSend: only local link partner is allowed + to send PAUSE frames + -- None = no link partner is allowed to send PAUSE frames + +NOTE: This parameter is ignored if auto-negotiation is set to "Off". + +Role in Master-Slave-Negotiation (1000Base-T only) +-------------------------------------------------- +Parameter: Role_? +Values: Auto, Master, Slave +Default: Auto + +This parameter is only valid for the SK-9821 and SK-9822 adapters. +For two 1000Base-T ports to communicate, one must take the role of the +master (providing timing information), while the other must be the +slave. Usually, this is negotiated between the two ports during link +establishment. If this fails, a port can be forced to a specific setting +with this parameter. + + +4.2 Adapter Parameters +----------------------- + +Connection Type (SK-98xx V2.0 copper adapters only) +--------------- +Parameter: ConType +Values: Auto, 100FD, 100HD, 10FD, 10HD +Default: Auto + +The parameter 'ConType' is a combination of all five per-port parameters +within one single parameter. This simplifies the configuration of both ports +of an adapter card! The different values of this variable reflect the most +meaningful combinations of port parameters. + +The following table shows the values of 'ConType' and the corresponding +combinations of the per-port parameters: + + ConType | DupCap AutoNeg FlowCtrl Role Speed + ----------+------------------------------------------------------ + Auto | Both On SymOrRem Auto Auto + 100FD | Full Off None Auto (ignored) 100 + 100HD | Half Off None Auto (ignored) 100 + 10FD | Full Off None Auto (ignored) 10 + 10HD | Half Off None Auto (ignored) 10 + +Stating any other port parameter together with this 'ConType' variable +will result in a merged configuration of those settings. This due to +the fact, that the per-port parameters (e.g. Speed_? ) have a higher +priority than the combined variable 'ConType'. + +NOTE: This parameter is always used on both ports of the adapter card. + +Interrupt Moderation +-------------------- +Parameter: Moderation +Values: None, Static, Dynamic +Default: None + +Interrupt moderation is employed to limit the maximum number of interrupts +the driver has to serve. That is, one or more interrupts (which indicate any +transmit or receive packet to be processed) are queued until the driver +processes them. When queued interrupts are to be served, is determined by the +'IntsPerSec' parameter, which is explained later below. + +Possible modes: + + -- None - No interrupt moderation is applied on the adapter card. + Therefore, each transmit or receive interrupt is served immediately + as soon as it appears on the interrupt line of the adapter card. + + -- Static - Interrupt moderation is applied on the adapter card. + All transmit and receive interrupts are queued until a complete + moderation interval ends. If such a moderation interval ends, all + queued interrupts are processed in one big bunch without any delay. + The term 'static' reflects the fact, that interrupt moderation is + always enabled, regardless how much network load is currently + passing via a particular interface. In addition, the duration of + the moderation interval has a fixed length that never changes while + the driver is operational. + + -- Dynamic - Interrupt moderation might be applied on the adapter card, + depending on the load of the system. If the driver detects that the + system load is too high, the driver tries to shield the system against + too much network load by enabling interrupt moderation. If - at a later + time - the CPU utilization decreases again (or if the network load is + negligible) the interrupt moderation will automatically be disabled. + +Interrupt moderation should be used when the driver has to handle one or more +interfaces with a high network load, which - as a consequence - leads also to a +high CPU utilization. When moderation is applied in such high network load +situations, CPU load might be reduced by 20-30%. + +NOTE: The drawback of using interrupt moderation is an increase of the round- +trip-time (RTT), due to the queueing and serving of interrupts at dedicated +moderation times. + +Interrupts per second +--------------------- +Parameter: IntsPerSec +Values: 30...40000 (interrupts per second) +Default: 2000 + +This parameter is only used if either static or dynamic interrupt moderation +is used on a network adapter card. Using this parameter if no moderation is +applied will lead to no action performed. + +This parameter determines the length of any interrupt moderation interval. +Assuming that static interrupt moderation is to be used, an 'IntsPerSec' +parameter value of 2000 will lead to an interrupt moderation interval of +500 microseconds. + +NOTE: The duration of the moderation interval is to be chosen with care. +At first glance, selecting a very long duration (e.g. only 100 interrupts per +second) seems to be meaningful, but the increase of packet-processing delay +is tremendous. On the other hand, selecting a very short moderation time might +compensate the use of any moderation being applied. + + +Preferred Port +-------------- +Parameter: PrefPort +Values: A, B +Default: A + +This is used to force the preferred port to A or B (on dual-port network +adapters). The preferred port is the one that is used if both are detected +as fully functional. + +RLMT Mode (Redundant Link Management Technology) +------------------------------------------------ +Parameter: RlmtMode +Values: CheckLinkState,CheckLocalPort, CheckSeg, DualNet +Default: CheckLinkState + +RLMT monitors the status of the port. If the link of the active port +fails, RLMT switches immediately to the standby link. The virtual link is +maintained as long as at least one 'physical' link is up. + +Possible modes: + + -- CheckLinkState - Check link state only: RLMT uses the link state + reported by the adapter hardware for each individual port to + determine whether a port can be used for all network traffic or + not. + + -- CheckLocalPort - In this mode, RLMT monitors the network path + between the two ports of an adapter by regularly exchanging packets + between them. This mode requires a network configuration in which + the two ports are able to "see" each other (i.e. there must not be + any router between the ports). + + -- CheckSeg - Check local port and segmentation: This mode supports the + same functions as the CheckLocalPort mode and additionally checks + network segmentation between the ports. Therefore, this mode is only + to be used if Gigabit Ethernet switches are installed on the network + that have been configured to use the Spanning Tree protocol. + + -- DualNet - In this mode, ports A and B are used as separate devices. + If you have a dual port adapter, port A will be configured as eth0 + and port B as eth1. Both ports can be used independently with + distinct IP addresses. The preferred port setting is not used. + RLMT is turned off. + +NOTE: RLMT modes CLP and CLPSS are designed to operate in configurations + where a network path between the ports on one adapter exists. + Moreover, they are not designed to work where adapters are connected + back-to-back. +*** + + +5 Large Frame Support +====================== + +The driver supports large frames (also called jumbo frames). Using large +frames can result in an improved throughput if transferring large amounts +of data. +To enable large frames, set the MTU (maximum transfer unit) of the +interface to the desired value (up to 9000), execute the following +command: + ifconfig eth0 mtu 9000 +This will only work if you have two adapters connected back-to-back +or if you use a switch that supports large frames. When using a switch, +it should be configured to allow large frames and auto-negotiation should +be set to OFF. The setting must be configured on all adapters that can be +reached by the large frames. If one adapter is not set to receive large +frames, it will simply drop them. + +You can switch back to the standard ethernet frame size by executing the +following command: + ifconfig eth0 mtu 1500 + +To permanently configure this setting, add a script with the 'ifconfig' +line to the system startup sequence (named something like "S99sk98lin" +in /etc/rc.d/rc2.d). +*** + + +6 VLAN and Link Aggregation Support (IEEE 802.1, 802.1q, 802.3ad) +================================================================== + +The Marvell Yukon/SysKonnect Linux drivers are able to support VLAN and +Link Aggregation according to IEEE standards 802.1, 802.1q, and 802.3ad. +These features are only available after installation of open source +modules available on the Internet: +For VLAN go to: http://www.candelatech.com/~greear/vlan.html +For Link Aggregation go to: http://www.st.rim.or.jp/~yumo + +NOTE: SysKonnect GmbH does not offer any support for these open source + modules and does not take the responsibility for any kind of + failures or problems arising in connection with these modules. + +NOTE: Configuring Link Aggregation on a SysKonnect dual link adapter may + cause problems when unloading the driver. + + +7 Troubleshooting +================== + +If any problems occur during the installation process, check the +following list: + + +Problem: The SK-98xx adapter cannot be found by the driver. +Solution: In /proc/pci search for the following entry: + 'Ethernet controller: SysKonnect SK-98xx ...' + If this entry exists, the SK-98xx or SK-98xx V2.0 adapter has + been found by the system and should be operational. + If this entry does not exist or if the file '/proc/pci' is not + found, there may be a hardware problem or the PCI support may + not be enabled in your kernel. + The adapter can be checked using the diagnostics program which + is available on the SysKonnect web site: + www.syskonnect.com + + Some COMPAQ machines have problems dealing with PCI under Linux. + This problem is described in the 'PCI howto' document + (included in some distributions or available from the + web, e.g. at 'www.linux.org'). + + +Problem: Programs such as 'ifconfig' or 'route' cannot be found or the + error message 'Operation not permitted' is displayed. +Reason: You are not logged in as user 'root'. +Solution: Logout and login as 'root' or change to 'root' via 'su'. + + +Problem: Upon use of the command 'ping <address>' the message + "ping: sendto: Network is unreachable" is displayed. +Reason: Your route is not set correctly. +Solution: If you are using RedHat, you probably forgot to set up the + route in the 'network configuration'. + Check the existing routes with the 'route' command and check + if an entry for 'eth0' exists, and if so, if it is set correctly. + + +Problem: The driver can be started, the adapter is connected to the + network, but you cannot receive or transmit any packets; + e.g. 'ping' does not work. +Reason: There is an incorrect route in your routing table. +Solution: Check the routing table with the command 'route' and read the + manual help pages dealing with routes (enter 'man route'). + +NOTE: Although the 2.2.x kernel versions generate the routing entry + automatically, problems of this kind may occur here as well. We've + come across a situation in which the driver started correctly at + system start, but after the driver has been removed and reloaded, + the route of the adapter's network pointed to the 'dummy0'device + and had to be corrected manually. + + +Problem: Your computer should act as a router between multiple + IP subnetworks (using multiple adapters), but computers in + other subnetworks cannot be reached. +Reason: Either the router's kernel is not configured for IP forwarding + or the routing table and gateway configuration of at least one + computer is not working. + +Problem: Upon driver start, the following error message is displayed: + "eth0: -- ERROR -- + Class: internal Software error + Nr: 0xcc + Msg: SkGeInitPort() cannot init running ports" +Reason: You are using a driver compiled for single processor machines + on a multiprocessor machine with SMP (Symmetric MultiProcessor) + kernel. +Solution: Configure your kernel appropriately and recompile the kernel or + the modules. + + + +If your problem is not listed here, please contact SysKonnect's technical +support for help (linux@syskonnect.de). +When contacting our technical support, please ensure that the following +information is available: +- System Manufacturer and HW Informations (CPU, Memory... ) +- PCI-Boards in your system +- Distribution +- Kernel version +- Driver version +*** + + + +***End of Readme File*** diff --git a/Documentation/thinkpad-acpi.txt b/Documentation/thinkpad-acpi.txt index eb2f5986e1eb..60953d6c919d 100644 --- a/Documentation/thinkpad-acpi.txt +++ b/Documentation/thinkpad-acpi.txt @@ -1,7 +1,7 @@ ThinkPad ACPI Extras Driver - Version 0.15 - July 1st, 2007 + Version 0.16 + August 2nd, 2007 Borislav Deianov <borislav@users.sf.net> Henrique de Moraes Holschuh <hmh@hmh.eng.br> @@ -161,20 +161,22 @@ system. Enabling the hotkey functionality of thinkpad-acpi signals the firmware that such a driver is present, and modifies how the ThinkPad firmware will behave in many situations. +The driver enables the hot key feature automatically when loaded. The +feature can later be disabled and enabled back at runtime. The driver +will also restore the hot key feature to its previous state and mask +when it is unloaded. + When the hotkey feature is enabled and the hot key mask is set (see -below), the various hot keys either generate ACPI events in the -following format: +below), the driver will report HKEY events in the following format: ibm/hotkey HKEY 00000080 0000xxxx -or events over the input layer. The input layer support accepts the -standard IOCTLs to remap the keycodes assigned to each hotkey. +Some of these events refer to hot key presses, but not all. -When the input device is open, the driver will suppress any ACPI hot key -events that get translated into a meaningful input layer event, in order -to avoid sending duplicate events to userspace. Hot keys that are -mapped to KEY_RESERVED in the keymap are not translated, and will always -generate an ACPI ibm/hotkey HKEY event, and no input layer events. +The driver will generate events over the input layer for hot keys and +radio switches, and over the ACPI netlink layer for other events. The +input layer support accepts the standard IOCTLs to remap the keycodes +assigned to each hot key. The hot key bit mask allows some control over which hot keys generate events. If a key is "masked" (bit set to 0 in the mask), the firmware @@ -256,6 +258,20 @@ sysfs notes: disabled" postition, and 1 if the switch is in the "radios enabled" position. + hotkey_report_mode: + Returns the state of the procfs ACPI event report mode + filter for hot keys. If it is set to 1 (the default), + all hot key presses are reported both through the input + layer and also as ACPI events through procfs (but not + through netlink). If it is set to 2, hot key presses + are reported only through the input layer. + + This attribute is read-only in kernels 2.6.23 or later, + and read-write on earlier kernels. + + May return -EPERM (write access locked out by module + parameter) or -EACCES (read-only). + input layer notes: A Hot key is mapped to a single input layer EV_KEY event, possibly @@ -393,21 +409,63 @@ unknown by the driver if the ThinkPad firmware triggered these events on hot key press or release, but the firmware will do it for either one, not both. -If a key is mapped to KEY_RESERVED, it generates no input events at all, -and it may generate a legacy thinkpad-acpi ACPI hotkey event. - +If a key is mapped to KEY_RESERVED, it generates no input events at all. If a key is mapped to KEY_UNKNOWN, it generates an input event that -includes an scan code, and it may also generate a legacy thinkpad-acpi -ACPI hotkey event. - -If a key is mapped to anything else, it will only generate legacy -thinkpad-acpi ACPI hotkey events if nobody has opened the input device. +includes an scan code. If a key is mapped to anything else, it will +generate input device EV_KEY events. Non hot-key ACPI HKEY event map: 0x5001 Lid closed 0x5002 Lid opened 0x7000 Radio Switch may have changed state +The above events are not propagated by the driver, except for legacy +compatibility purposes when hotkey_report_mode is set to 1. + +Compatibility notes: + +ibm-acpi and thinkpad-acpi 0.15 (mainline kernels before 2.6.23) never +supported the input layer, and sent events over the procfs ACPI event +interface. + +To avoid sending duplicate events over the input layer and the ACPI +event interface, thinkpad-acpi 0.16 implements a module parameter +(hotkey_report_mode), and also a sysfs device attribute with the same +name. + +Make no mistake here: userspace is expected to switch to using the input +layer interface of thinkpad-acpi, together with the ACPI netlink event +interface in kernels 2.6.23 and later, or with the ACPI procfs event +interface in kernels 2.6.22 and earlier. + +If no hotkey_report_mode module parameter is specified (or it is set to +zero), the driver defaults to mode 1 (see below), and on kernels 2.6.22 +and earlier, also allows one to change the hotkey_report_mode through +sysfs. In kernels 2.6.23 and later, where the netlink ACPI event +interface is available, hotkey_report_mode cannot be changed through +sysfs (it is read-only). + +If the hotkey_report_mode module parameter is set to 1 or 2, it cannot +be changed later through sysfs (any writes will return -EPERM to signal +that hotkey_report_mode was locked. On 2.6.23 and later, where +hotkey_report_mode cannot be changed at all, writes will return -EACES). + +hotkey_report_mode set to 1 makes the driver export through the procfs +ACPI event interface all hot key presses (which are *also* sent to the +input layer). This is a legacy compatibility behaviour, and it is also +the default mode of operation for the driver. + +hotkey_report_mode set to 2 makes the driver filter out the hot key +presses from the procfs ACPI event interface, so these events will only +be sent through the input layer. Userspace that has been updated to use +the thinkpad-acpi input layer interface should set hotkey_report_mode to +2. + +Hot key press events are never sent to the ACPI netlink event interface. +Really up-to-date userspace under kernel 2.6.23 and later is to use the +netlink interface and the input layer interface, and don't bother at all +with hotkey_report_mode. + Bluetooth --------- diff --git a/Documentation/video4linux/cx2341x/fw-encoder-api.txt b/Documentation/video4linux/cx2341x/fw-encoder-api.txt index 5dd3109a8b3f..5a27af2ee1c6 100644 --- a/Documentation/video4linux/cx2341x/fw-encoder-api.txt +++ b/Documentation/video4linux/cx2341x/fw-encoder-api.txt @@ -407,8 +407,10 @@ Description u32 length; // Length of this frame u32 offset_low; // Offset in the file of the u32 offset_high; // start of this frame - u32 mask1; // Bits 0-1 are the type mask: + u32 mask1; // Bits 0-2 are the type mask: // 1=I, 2=P, 4=B + // 0=End of Program Index, other fields + // are invalid. u32 pts; // The PTS of the frame u32 mask2; // Bit 0 is bit 32 of the pts. }; |