summaryrefslogtreecommitdiff
path: root/Documentation/power/power_supply_class.txt
diff options
context:
space:
mode:
authorLiam Breck <kernel@networkimprov.net>2017-06-07 11:37:52 -0700
committerSebastian Reichel <sebastian.reichel@collabora.co.uk>2017-06-08 16:29:28 +0200
commit413de34ab93edc80ef710c54ceb0987b8496aef3 (patch)
treed9c1addd8cd5673e71c10f218a97b9048e701909 /Documentation/power/power_supply_class.txt
parentc08b1f45d7d193b3e6dcbbf30d403cb49b667b8c (diff)
power: supply: core: Add power_supply_prop_precharge
Battery chargers use POWER_SUPPLY_PROP_PRECHARGE_CURRENT Clarify related item POWER_SUPPLY_PROP_CHARGE_TERM_CURRENT Signed-off-by: Liam Breck <kernel@networkimprov.net> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
Diffstat (limited to 'Documentation/power/power_supply_class.txt')
-rw-r--r--Documentation/power/power_supply_class.txt19
1 files changed, 12 insertions, 7 deletions
diff --git a/Documentation/power/power_supply_class.txt b/Documentation/power/power_supply_class.txt
index 01f007591070..300d37896e51 100644
--- a/Documentation/power/power_supply_class.txt
+++ b/Documentation/power/power_supply_class.txt
@@ -115,28 +115,33 @@ of charge when battery became full/empty". It also could mean "value of
charge when battery considered full/empty at given conditions (temperature,
age)". I.e. these attributes represents real thresholds, not design values.
+ENERGY_FULL, ENERGY_EMPTY - same as above but for energy.
+
CHARGE_COUNTER - the current charge counter (in µAh). This could easily
be negative; there is no empty or full value. It is only useful for
relative, time-based measurements.
+PRECHARGE_CURRENT - the maximum charge current during precharge phase
+of charge cycle (typically 20% of battery capacity).
+CHARGE_TERM_CURRENT - Charge termination current. The charge cycle
+terminates when battery voltage is above recharge threshold, and charge
+current is below this setting (typically 10% of battery capacity).
+
CONSTANT_CHARGE_CURRENT - constant charge current programmed by charger.
CONSTANT_CHARGE_CURRENT_MAX - maximum charge current supported by the
power supply object.
-INPUT_CURRENT_LIMIT - input current limit programmed by charger. Indicates
-the current drawn from a charging source.
-CHARGE_TERM_CURRENT - Charge termination current used to detect the end of charge
-condition.
-
-CALIBRATE - battery or coulomb counter calibration status
CONSTANT_CHARGE_VOLTAGE - constant charge voltage programmed by charger.
CONSTANT_CHARGE_VOLTAGE_MAX - maximum charge voltage supported by the
power supply object.
+INPUT_CURRENT_LIMIT - input current limit programmed by charger. Indicates
+the current drawn from a charging source.
+
CHARGE_CONTROL_LIMIT - current charge control limit setting
CHARGE_CONTROL_LIMIT_MAX - maximum charge control limit setting
-ENERGY_FULL, ENERGY_EMPTY - same as above but for energy.
+CALIBRATE - battery or coulomb counter calibration status
CAPACITY - capacity in percents.
CAPACITY_ALERT_MIN - minimum capacity alert value in percents.