diff options
author | Axel Lin <axel.lin@ingics.com> | 2014-04-15 19:58:42 +0800 |
---|---|---|
committer | Mark Brown <broonie@linaro.org> | 2014-06-01 13:42:42 +0100 |
commit | b88703567b6ca3fc183b22eb5e852b4bf5679d72 (patch) | |
tree | 7ca0ebe03917c3d792ecadb86b275d91e11cec09 | |
parent | a6016c523ef2f86d4ec60b87b480dd1a2c5ae33a (diff) |
regulator: axp20x: Use regulator_map_voltage_ascend for LDO4
The voltages in axp20x_ldo4_data table are in ascendant order, so use
regulator_map_voltage_ascend.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
-rw-r--r-- | drivers/regulator/axp20x-regulator.c | 1 |
1 files changed, 1 insertions, 0 deletions
diff --git a/drivers/regulator/axp20x-regulator.c b/drivers/regulator/axp20x-regulator.c index 61ae4d4fbdd0..004aadb7bcc1 100644 --- a/drivers/regulator/axp20x-regulator.c +++ b/drivers/regulator/axp20x-regulator.c @@ -111,6 +111,7 @@ static struct regulator_ops axp20x_ops_table = { .set_voltage_sel = regulator_set_voltage_sel_regmap, .get_voltage_sel = regulator_get_voltage_sel_regmap, .list_voltage = regulator_list_voltage_table, + .map_voltage = regulator_map_voltage_ascend, .enable = regulator_enable_regmap, .disable = regulator_disable_regmap, .is_enabled = regulator_is_enabled_regmap, |