diff options
author | Viresh Kumar <viresh.kumar@linaro.org> | 2018-02-09 14:28:10 +0530 |
---|---|---|
committer | Eduardo Valentin <edubezval@gmail.com> | 2018-04-18 07:04:28 -0700 |
commit | e04907dbc25930b88ee2328fe692c776f63ddf2c (patch) | |
tree | cb42b150a52b62e6e101b0b47b805e5939d3c12c | |
parent | 8b8b5903d50d6e4c5fd06272022b25a11c3214cf (diff) |
dt-bindings: thermal: Remove "cooling-{min|max}-level" properties
The "cooling-min-level" and "cooling-max-level" properties are not
parsed by any part of kernel currently and the max cooling state of a
CPU cooling device is found by referring to the cpufreq table instead.
Remove the unused bindings.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Rob Herring <robh@kernel.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
-rw-r--r-- | Documentation/devicetree/bindings/thermal/thermal.txt | 16 |
1 files changed, 1 insertions, 15 deletions
diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt index 1719d47a5e2f..cc553f0952c5 100644 --- a/Documentation/devicetree/bindings/thermal/thermal.txt +++ b/Documentation/devicetree/bindings/thermal/thermal.txt @@ -55,8 +55,7 @@ of heat dissipation). For example a fan's cooling states correspond to the different fan speeds possible. Cooling states are referred to by single unsigned integers, where larger numbers mean greater heat dissipation. The precise set of cooling states associated with a device -(as referred to by the cooling-min-level and cooling-max-level -properties) should be defined in a particular device's binding. +should be defined in a particular device's binding. For more examples of cooling devices, refer to the example sections below. Required properties: @@ -69,15 +68,6 @@ Required properties: See Cooling device maps section below for more details on how consumers refer to cooling devices. -Optional properties: -- cooling-min-level: An integer indicating the smallest - Type: unsigned cooling state accepted. Typically 0. - Size: one cell - -- cooling-max-level: An integer indicating the largest - Type: unsigned cooling state accepted. - Size: one cell - * Trip points The trip node is a node to describe a point in the temperature domain @@ -226,8 +216,6 @@ cpus { 396000 950000 198000 850000 >; - cooling-min-level = <0>; - cooling-max-level = <3>; #cooling-cells = <2>; /* min followed by max */ }; ... @@ -241,8 +229,6 @@ cpus { */ fan0: fan@48 { ... - cooling-min-level = <0>; - cooling-max-level = <9>; #cooling-cells = <2>; /* min followed by max */ }; }; |